Literature DB >> 9487468

Myocardial perfusion characteristics and hemodynamic profile of MRX-115, a venous echocardiographic contrast agent, during acute myocardial infarction.

J R Lindner1, C Firschke, K Wei, N C Goodman, D M Skyba, S Kaul.   

Abstract

We sought to determine whether MRX-115, a new venous echocardiographic contrast agent, could accurately assess risk area during coronary occlusion and infarct size after reperfusion by using novel imaging modalities meant to selectively enhance contrast signals. In 12 open-chest dogs, venous injections of 0.5 ml of MRX-115 were performed during baseline and coronary occlusion and after reperfusion in the presence of exogenous hyperemia. Ultrasound was transmitted at 2 MHz and received at both 2 MHz (fundamental) and 4 MHz (harmonic) frequencies during continuous and intermittent (end-systolic only) imaging. The risk area during coronary occlusion was compared with technetium autoradiography, and the infarct size after reperfusion was compared with postmortem tissue staining. MRX-115 produced no alterations in hemodynamic or pulmonary gas exchange at any stage. During continuous (both fundamental and harmonic) and intermittent fundamental imaging, measurements of perfusion defects were precluded in many dogs by either poor signal enhancement or posterior wall attenuation. By comparison, these measurements were possible during intermittent harmonic imaging in all dogs except one, which had a very small infarction during reflow. Correlation analysis between perfusion defect size on intermittent harmonic imaging and either autoradiographic risk area or postmortem infarct size gave r values of 0.83 and 0.92, respectively. We conclude that MRX-115 is hemodynamically well tolerated and, when imaging is performed after venous injection, can accurately assess regions of hypoperfusion when combined with intermittent harmonic imaging. These results are promising for the use of this approach in patients with acute myocardial infarction.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9487468     DOI: 10.1016/s0894-7317(98)70118-x

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  4 in total

1.  Quantitative assessment of right ventricular systolic function by the analysis of right ventricular contrast time-intensity curve.

Authors:  Lin Wang; Youbin Deng; Tianliang Li; Haoyi Yang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2004

Review 2.  New ultrasound contrast agents for left ventricular and myocardial opacification.

Authors:  J D Kasprzak; F J Ten Cate
Journal:  Herz       Date:  1998-12       Impact factor: 1.443

3.  Changes in transmural distribution of myocardial perfusion assessed by quantitative intravenous myocardial contrast echocardiography in humans.

Authors:  S Fukuda; T Muro; T Hozumi; H Watanabe; K Shimada; M Yoshiyama; K Takeuchi; J Yoshikawa
Journal:  Heart       Date:  2002-10       Impact factor: 5.994

4.  Quantitative assessment of coronary flow reserve by the variables of time-intensity curve with myocardial contrast echocardiography.

Authors:  Xiaping Yuan; Xinfang Wang; Wangpeng Liu; Chunsong Kang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2002
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.