Literature DB >> 9486611

High dose rate brachytherapy for carcinoma of the cervix: risk factors for late rectal complications.

T Uno1, J Itami, M Aruga, K Kotaka, H Fujimoto, T Sato, S Minoura, H Ito.   

Abstract

PURPOSE: To determine the incidence of late rectal complications in patients treated with high dose rate brachytherapy for FIGO Stage IIB, IIIB carcinoma of the uterine cervix, and to evaluate the treatment factors associated with an increased probability of treatment complications. METHODS AND MATERIALS: Records of 100 patients with FIGO IIB and IIIB cervical carcinoma treated with definitive irradiation using high dose rate intracavitary brachytherapy (HDR-ICR) between 1977 and 1994 were retrospectively reviewed. For each HDR-ICR session, 6-Gy isodose volume was reconstructed retrospectively and the relationship between probability of late rectal complications and several treatment factors, including a specific point dose and parameters representing isodose volume, were examined. Statistical analyses were performed to determine the treatment factors predictive of late rectal complications.
RESULTS: Of patients treated for both stages, 33% and 38% had experienced moderate to severe (Grade 2-4) complications at 3 and 5 years, respectively. Mean value of depth (D) of 6-Gy isodose volume in HDR-ICR in patients with and without complication were 51 mm and 46 mm, respectively (p = 0.0070). A significant difference was noted in complication rate between patients with D > 51 mm and D < or = 51 mm (p = 0.0023). Cumulative Point S (2 cm dorsal from the midpoint of the ovoid sources) dose (p = 0.044), and single or total point S dose by HDR-ICR (p = 0.019, each) were significantly higher in patients who developed complication, whereas these factors did not significantly affect the probability of pelvic control. Multivariate analysis revealed that D was the independent predictor for the endpoint of actuarial complication rate (p = 0.047). No significant difference was noted in the product of L, D, and W value (L x D x W) between patients with less than Grade 2 rectal complication and those with Grade 2-4.
CONCLUSION: Depth of 6-Gy isodose volume determined three dimensionally (3D) has the predictive value of late rectal complications. This suggests that the shape of the high dose area in HDR-ICR influences the incidence of late rectal complications regardless of its volume.

Entities:  

Mesh:

Year:  1998        PMID: 9486611     DOI: 10.1016/s0360-3016(97)00849-3

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  3 in total

1.  Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer.

Authors:  Obed Rachel Ibhade; Oyekunle Emmanuel Oyeyemi; Akinlade Bidemi Idayat; Ntekim Atara I
Journal:  J Contemp Brachytherapy       Date:  2015-04-01

2.  A prospective randomized study on two dose fractionation regimens of high-dose-rate brachytherapy for carcinoma of the uterine cervix: comparison of efficacies and toxicities between two regimens.

Authors:  Taek Keun Nam; Sung Ja Ahn
Journal:  J Korean Med Sci       Date:  2004-02       Impact factor: 2.153

3.  Clinical analysis of speculum-based vaginal packing for high-dose-rate intracavitary tandem and ovoid brachytherapy in cervical cancer.

Authors:  Shivani Sud; Toni Roth; Ellen Jones
Journal:  J Contemp Brachytherapy       Date:  2018-02-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.