Literature DB >> 9485139

Agreement and reproducibility of automatic versus manual measurement of QT interval and QT dispersion.

I Savelieva1, G Yi, X Guo, K Hnatkova, M Malik.   

Abstract

To determine whether the automatic measurement of the QT interval is consistent with the manual measurement, this study evaluated the reproducibility and agreement of both methods in 70 normal subjects and 54 patients with hypertrophic cardiomyopathy. The mean, minimum, and maximum QT interval and QT dispersion were computed in a set of 6 consecutive electrocardiograms (3 in the supine and 3 in the standing position) obtained from each subject. The automatic method determined the T-wave end as the intersect of the least-squares-fit line around the tangent to the T-wave downslope with the isoelectric baseline. Manual measurements were obtained using a high-resolution digitizing board. QT dispersion was defined as the difference between the maximum and minimum QT interval and as standard deviations of the QT interval duration in all and precordial leads. In patients with hypertrophic cardiomyopathy, the absolute values of the QT interval and QT dispersion were significantly higher than those in normal subjects (p < 0.0001). In both groups, the intrasubject variability of the QT interval was significantly lower with automatic than with manual measurement (p < 0.05). The agreement between automatic and manual QT interval measurements was surprisingly poor, but it was better in patients with hypertrophic cardiomyopathy (r2 = 0.46 to 0.67) than in normal subjects (r2 = 0.10 to 0.25). In both groups, the reproducibility and agreement of both methods for QT dispersion were significantly poorer than for QT interval. Hence, the automatic QT interval measurements are more stable and reproducible than manual measurement, but the lack of agreement between manual and automatic measurement suggests that clinical experience gained with manual assessment cannot be applied blindly to data obtained from the automatic systems.

Entities:  

Mesh:

Year:  1998        PMID: 9485139     DOI: 10.1016/s0002-9149(97)00927-2

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  25 in total

1.  Evaluation of serial QT dispersion in patients with first non-Q-wave myocardial infarction: relation to the severity of underlying coronary artery disease.

Authors:  T G Lyras; V A Papapanagiotou; M G Foukarakis; F K Panou; N D Skampas; J A Lakoumentas; C V Priftis; A A Zacharoulis
Journal:  Clin Cardiol       Date:  2003-04       Impact factor: 2.882

2.  Computer-based analysis of dynamic QT changes: toward high precision and individual rate correction.

Authors:  Corina Dota; Bo Skallefell; Nils Edvardsson; Gunnar Fager
Journal:  Ann Noninvasive Electrocardiol       Date:  2002-10       Impact factor: 1.468

Review 3.  Drugs, QTc interval prolongation and final ICH E14 guideline : an important milestone with challenges ahead.

Authors:  Rashmi R Shah
Journal:  Drug Saf       Date:  2005       Impact factor: 5.606

Review 4.  [Clinical significance of dynamic QT-interval-analyses].

Authors:  H Bonnemeier
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2007-03

5.  Magnitude, mechanism, and reproducibility of QT interval differences between superimposed global and individual lead ECG complexes.

Authors:  Paul Kligfield; Benoit Tyl; Martine Maarek; Pierre Maison-Blanche
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-04       Impact factor: 1.468

6.  QT interval prolongation in end-stage liver disease cannot be explained by nonhepatic factors.

Authors:  Divyang Patel; Prabhpreet Singh; William Katz; Christopher Hughes; Kapil Chopra; Jan Němec
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-04-24       Impact factor: 1.468

Review 7.  Assessing QT interval prolongation and its associated risks with antipsychotics.

Authors:  Jimmi Nielsen; Claus Graff; Jørgen K Kanters; Egon Toft; David Taylor; Jonathan M Meyer
Journal:  CNS Drugs       Date:  2011-06-01       Impact factor: 5.749

8.  QT dispersion in uncomplicated familial Mediterranean fever.

Authors:  Naomi Nussinovitch; Avi Livneh; Keren Katz; Pnina Langevitz; Olga Feld; Moshe Nussinovitch; Benjamin Volovitz; Merav Lidar; Udi Nussinovitch
Journal:  Clin Rheumatol       Date:  2010-04-11       Impact factor: 2.980

9.  The relation of QT dispersion and localized QT difference to coronary pathology in a population with unstable coronary artery disease.

Authors:  Milos Kesek; Anders Englund; Tomas Jernberg; Bo Lagerqvist; Bertil Lindahl
Journal:  Ann Noninvasive Electrocardiol       Date:  2003-01       Impact factor: 1.468

10.  Abnormalities of the repolarization characteristics of patients with heart failure progress with symptom severity.

Authors:  Christopher C E Lang; James M M Neilson; Andrew D Flapan
Journal:  Ann Noninvasive Electrocardiol       Date:  2004-07       Impact factor: 1.468

View more