Literature DB >> 9484370

Subtraction ictal SPECT co-registered to MRI improves clinical usefulness of SPECT in localizing the surgical seizure focus.

T J O'Brien1, E L So, B P Mullan, M F Hauser, B H Brinkmann, N I Bohnen, D Hanson, G D Cascino, C R Jack, F W Sharbrough.   

Abstract

Traditional side-by-side visual interpretation of ictal and interictal single-photon emission computed tomography (SPECT) scans can be difficult in identifying the surgical focus, particularly in patients with extratemporal or otherwise unlocalized intractable epilepsy. Computer-aided subtraction ictal SPECT co-registered to MRI (SISCOM) may improve the clinical usefulness of SPECT in localizing the surgical seizure focus. We studied 51 consecutive intractable partial epilepsy patients who had interictal and ictal scans. The SPECT studies were blindly reviewed and classified as either localizing to 1 of 16 sites in the brain or as nonlocalizing. SISCOM images were localizing in 45 of 51 (88.2%) compared with 20 of 51 (39.2%) for traditional side-by-side inspection of ictal and interictal SPECT images (p < 0.0001). Inter-rater agreement for two independent reviewers was better for SISCOM (84.3% versus 41.2%, kappa = 0.83 versus 0.26; p < 0.0001). Concordance of seizure localization with the more established tests was also higher for SISCOM. Late injection of the radiotracer (> 45 seconds), but not secondary generalization of the seizure, was associated with a falsely localizing or nonlocalizing SISCOM. Epilepsy surgery patients whose SISCOM localization was concordant with a falsely localizing or nonlocalizing SISCOM. Epilepsy surgery patients whose SISCOM localization was concordant with the surgical site were more likely to have excellent outcome than patients with nonconcordant or nonlocalizing findings (62.5% [10/16] versus 20% [2/10]; p < 0.05). On the other hand, seizure localization by the traditional method of SPECT inspection had no significant association with postsurgical outcome. We conclude that SISCOM improves the sensitivity and the specificity of SPECT in localizing the seizure focus for epilepsy surgery. Concordance between SISCOM localization and site of surgery is predictive of postsurgical improvement in seizure outcome.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9484370     DOI: 10.1212/wnl.50.2.445

Source DB:  PubMed          Journal:  Neurology        ISSN: 0028-3878            Impact factor:   9.910


  65 in total

Review 1.  Imaging of brain function using SPECT.

Authors:  James M Warwick
Journal:  Metab Brain Dis       Date:  2004-06       Impact factor: 3.584

2.  Continuous or emergent EEG: can bedside caregivers recognize epileptiform discharges?

Authors:  Enrique C Leira; Mary E Bertrand; R Edward Hogan; Salvador Cruz-Flores; Kathleen W Wyrwich; Osamah J Albaker; Eve M Holzemer
Journal:  Intensive Care Med       Date:  2003-11-13       Impact factor: 17.440

3.  3D for Define Implantation Targets, Distinguish Eloquent Cortex, or Desist From Invasive Monitoring.

Authors:  Mohamad Koubeissi
Journal:  Epilepsy Curr       Date:  2015 Nov-Dec       Impact factor: 7.500

Review 4.  Neuroimaging of epilepsy.

Authors:  Fernando Cendes; William H Theodore; Benjamin H Brinkmann; Vlastimil Sulc; Gregory D Cascino
Journal:  Handb Clin Neurol       Date:  2016

Review 5.  Neuroimaging of epilepsy: therapeutic implications.

Authors:  Ruben I Kuzniecky
Journal:  NeuroRx       Date:  2005-04

6.  Joint reconstruction of Ictal/inter-ictal SPECT data for improved epileptic foci localization.

Authors:  Yothin Rakvongthai; Frederic Fahey; Korn Borvorntanajanya; Supatporn Tepmongkol; Usanee Vutrapongwatana; Katherine Zukotynski; Georges El Fakhri; Jinsong Ouyang
Journal:  Med Phys       Date:  2017-04       Impact factor: 4.071

7.  Intracranial electroencephalography seizure onset patterns and surgical outcomes in nonlesional extratemporal epilepsy.

Authors:  Nicholas M Wetjen; W Richard Marsh; Fredric B Meyer; Gregory D Cascino; Elson So; Jeffrey W Britton; S Matthew Stead; Gregory A Worrell
Journal:  J Neurosurg       Date:  2009-06       Impact factor: 5.115

8.  Validation of ictal single photon emission computed tomography with depth encephalography and epilepsy surgery.

Authors:  Vijay M Thadani; Alan Siegel; Petra Lewis; Adrian M Siegel; Barbara C Jobst; Karen L Gilbert; Terrance M Darcey; David W Roberts; Peter D Williamson
Journal:  Neurosurg Rev       Date:  2003-07-04       Impact factor: 3.042

9.  Seizure Freedom in Children With Pathology-Confirmed Focal Cortical Dysplasia.

Authors:  Anna Mrelashvili; Robert J Witte; Elaine C Wirrell; Katherine C Nickels; Lily C Wong-Kisiel
Journal:  Pediatr Neurol       Date:  2015-09-12       Impact factor: 3.372

10.  FocusDET, a new toolbox for SISCOM analysis. Evaluation of the registration accuracy using Monte Carlo simulation.

Authors:  Berta Martí Fuster; Oscar Esteban; Xavier Planes; Pablo Aguiar; Cristina Crespo; Carles Falcon; Gert Wollny; Sebastià Rubí Sureda; Xavier Setoain; Alejandro F Frangi; Maria J Ledesma; Andrés Santos; Javier Pavía; Domènec Ros
Journal:  Neuroinformatics       Date:  2013-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.