Acoustic performance and clinical use of a fibreoptic hydrophone.

A J Coleman1, E Draguioti, R Tiptaf, N Shotri, J E Saunders.   

Abstract

Initial clinical experience with the use of an optical fibre hydrophone for in vivo ultrasound dosimetry is reported. The hydrophone, originally described by Beard and Mills (1997), operates as an extrinsic, low-finesse Fabry-Perot optical sensor where acoustically-induced thickness changes in a polymer film modulate the phase difference between light beams reflected from the two surfaces of the film. The pressure waveforms from the sensor are compared with those from a calibrated piezoelectric polymer membrane hydrophone. The sensor is found to have a frequency resonance at around 12 MHz, corresponding to the thickness mode of the 50-micron polymer film. The directional responses at 0.16 MHz, 1.0 MHz and 5.0 MHz are found to be similar to those predicted for a plane piston receiver with the same diameter as that of the polymer film (400 microns). The performance of the sensor as a broad-band hydrophone is degraded by the relatively low acoustical impedance of the adhesive used in the fibre-film bond. The hydrophone was used in the clinic for measurement of acoustic pressures within the ureter of 4 patients undergoing clinical extracorporeal shock-wave lithotripsy on a Dornier HM3 lithotripter. Pressures in the range 0.5 to 5.0 MPa were recorded in the ureter at positions over 10 cm from the renal pelvis. Problems related to the clinical use of the sensor, including instability in the sensitivity of the sensor following handling and its mechanical strength in high-amplitude acoustic fields, are discussed.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9483782     DOI: 10.1016/s0301-5629(97)00236-6

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  4 in total

1.  Inexpensive Acoustoelectric Hydrophone For Mapping High Intensity Ultrasonic Fields.

Authors:  Russell S Witte; Tim Hall; Ragner Olafsson; Sheng-Wen Huang; Matthew O'Donnell
Journal:  J Appl Phys       Date:  2008       Impact factor: 2.546

2.  Effect of the body wall on lithotripter shock waves.

Authors:  Guangyan Li; James A McAteer; James C Williams; Zachary C Berwick
Journal:  J Endourol       Date:  2014-01-08       Impact factor: 2.942

3.  High-sensitivity fiber-optic ultrasound sensors for medical imaging applications.

Authors:  H Wen; D G Wiesler; A Tveten; B Danver; A Dandridge
Journal:  Ultrason Imaging       Date:  1998-04       Impact factor: 1.578

4.  Shielding of piezoelectric ultrasonic probes in Hall effect imaging.

Authors:  H Wen; E Bennett; D G Wiesler
Journal:  Ultrason Imaging       Date:  1998-07       Impact factor: 1.578

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.