Literature DB >> 9483772

Evaluation of model-based processing algorithms for averaged transmitral spectral Doppler images.

A F Hall1, S P Nudelman, S J Kovács.   

Abstract

In an effort to characterize more fully diastolic function using Doppler echocardiography, we have previously developed an automated method of model-based image processing for spectral Doppler images of transmitral blood flow. In this method, maximum velocity envelopes (MVEs) extracted from individual Doppler images are aligned and averaged over several cardiac cycles. The averaged waveform is fit by the solution of a kinematic model of diastolic filling. The results are estimates of the model parameters. As expected, the mean and standard deviation of the model parameter estimates depend on many factors such as noise, the number of cardiac cycles averaged, beat-to-beat variation, waveform shape, observation time and the processing methods used, among others. A comprehensive evaluation of these effects has not been performed to date. A simulation was developed to evaluate the performance of three automated processing methods and to measure the influence of noise, beat-to-beat variation and observation time on the model parameter estimates. The simulation's design and a description and analysis of the three automated processing methods are presented. Of the three methods evaluated, using the inflection point in the acceleration portion of the velocity contour as the first data point to be fit was found to be the most robust method for processing averaged E-wave MVE waveforms. Using this method under nominal conditions, the average bias was measured to be < 3% for each of the model parameters. As expected, the biases and standard deviations of the estimates increased as a result of increased noise levels, increased beat-to-beat variation and decreased observation time. Another important finding was that the effects of noise, beat-to-beat variation and waveform observation time on the parameter estimates are dependent on the location in model parameter space.

Mesh:

Year:  1998        PMID: 9483772     DOI: 10.1016/s0301-5629(97)00232-9

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  The diastolic function to cyclic variation of myocardial ultrasonic backscatter relation: the influence of parameterized diastolic filling (PDF) formalism determined chamber properties.

Authors:  Christopher W Lloyd; Leonid Shmuylovich; Mark R Holland; James G Miller; Sándor J Kovács
Journal:  Ultrasound Med Biol       Date:  2011-06-16       Impact factor: 2.998

2.  The kinematic filling efficiency index of the left ventricle: contrasting normal vs. diabetic physiology.

Authors:  Wei Zhang; Charles S Chung; Matt M Riordan; Yue Wu; Leonid Shmuylovich; Sándor J Kovács
Journal:  Ultrasound Med Biol       Date:  2007-05-03       Impact factor: 2.998

3.  The vortex formation time to diastolic function relation: assessment of pseudonormalized versus normal filling.

Authors:  Erina Ghosh; Sándor J Kovács
Journal:  Physiol Rep       Date:  2013-11-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.