Literature DB >> 9482392

The detection by enzyme-linked immunosorbent assays of non-complement-fixing HLA antibodies in transfusion medicine.

A Lubenko1, K M Rodi.   

Abstract

BACKGROUND: Noncomplement-fixing white cell antibodies have been demonstrated by the use of immunofluorescence flow cytometry against intact lymphocytes. However, such antibodies may be either HLA-specific or directed against other white cell antigens. Commercial enzyme-linked immunosorbent assay (ELISA) kits, using solubilized HLA molecules as targets, enable such HLA-specific antibodies to be detected in patients who are refractory to platelet transfusion, patients experiencing febrile transfusion reactions, and patients whose sera give nonspecific hemagglutination in indirect antiglobulin tests. STUDY DESIGN AND METHODS: Sera from all three groups of patients, previously screened for cytotoxic antibodies by using complement-dependent lymphocytotoxicity, were re-investigated with commercial ELISA kits for HLA antibody screening and identification using the manufacturers' recommended test methods.
RESULTS: Non-complement fixing HLA antibodies were detected by ELISA in many sera that were lymphocytotoxicity test-negative; that is, 14 (17.5%) of 80 from refractory patients, 8 (23.5%) of 34 from those with febrile reactions, and 11 (22.4%) of 49 from those with nonspecific hemagglutination in the direct antiglobulin test. However, not all cytotoxic white cell antibodies were detectable by ELISA: only 19 (82.6%) of 23, 19 (67.8%) of 28, and 11 (73.6%) of 49, respectively in the three groups. Similarly, only 143 (79.4%) of 181 cytotoxic sera with clear-cut HLA-A or -B locus specificities were detectable by ELISA.
CONCLUSION: ELISAs detect some but not all clinically significant HLA antibodies, irrespective of their ability to fix complement in vitro.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9482392     DOI: 10.1046/j.1537-2995.1998.38198141496.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  5 in total

Review 1.  Sensitive solid-phase detection of donor-specific antibodies as an aid highly relevant to improving allograft outcomes.

Authors:  Gerald Schlaf; Beatrix Pollok-Kopp; Wolfgang W Altermann
Journal:  Mol Diagn Ther       Date:  2014-04       Impact factor: 4.074

2.  HLA-antibody testing: the immune phagocytosis inhibition test is superior to the PRA-STAT and NIH lymphocytotoxic test with respect to specificity.

Authors:  B K Flesch; M Philipp; U Cassens; J Neppert
Journal:  J Clin Lab Anal       Date:  2001       Impact factor: 2.352

3.  Prevalence of HLA antibodies in remotely transfused or alloexposed volunteer blood donors.

Authors:  Ram M Kakaiya; Darrell J Triulzi; David J Wright; Whitney R Steele; Steven H Kleinman; Michael P Busch; Philip J Norris; Christopher D Hillyer; Jerome L Gottschall; Jorge A Rios; Patricia Carey; Simone A Glynn
Journal:  Transfusion       Date:  2010-01-08       Impact factor: 3.157

4.  Release of cytokines in stored whole blood and red cell concentrate: Effect of leukoreduction.

Authors:  Rinku Shukla; Tanvi Patel; Snehalata Gupte
Journal:  Asian J Transfus Sci       Date:  2015 Jul-Dec

5.  Novel solid phase-based ELISA assays contribute to an improved detection of anti-HLA antibodies and to an increased reliability of pre- and post-transplant crossmatching.

Authors:  Gerald Schlaf; Beatrix Pollok-Kopp; Till Manzke; Oliver Schurat; Wolfgang Altermann
Journal:  NDT Plus       Date:  2010-09-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.