Literature DB >> 9482182

Biological reactions to cerebrospinal fluid shunt devices: a review of the cellular pathology.

M R Del Bigio1.   

Abstract

OBJECTIVE: To understand the interaction between cerebrospinal fluid shunt components and the brain and other tissues.
METHODS: A systematic review of the medical literature directly pertaining to shunt complications, and that dealing with tissues' reactions to implants in general, was conducted.
RESULTS: Vascularized pedicles of glial tissue or choroid plexus grow into ventricular catheters, primarily as a mechanical phenomenon. Cellular debris or blood can cause dysfunction of valve components. Chronic inflammation, which is nonspecific, might contribute to degradation of the components.
CONCLUSION: Care must be taken to prevent early entry of debris or blood into the shunt system. Ventricular collapse onto the shunt must be avoided. Refinement of manufacturing methods or modification of shunt materials could reduce the susceptibility of shunts to infection and improve longevity of the apparatus.

Entities:  

Mesh:

Year:  1998        PMID: 9482182     DOI: 10.1097/00006123-199802000-00064

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  20 in total

1.  Deep brain stimulation complicated by bilateral large cystic cavitation around the leads in a patient with Parkinson's disease.

Authors:  Jonathan Jagid; Karthik Madhavan; Amade Bregy; Mehul Desai; Armando Ruiz; Robert Quencer; Howard J Landy
Journal:  BMJ Case Rep       Date:  2015-10-16

Review 2.  Ventricular shunt infections: immunopathogenesis and clinical management.

Authors:  Yenis Gutierrez-Murgas; Jessica N Snowden
Journal:  J Neuroimmunol       Date:  2014-08-13       Impact factor: 3.478

Review 3.  Nonfunctional abdominal complications of the distal catheter on the treatment of hydrocephalus: an inflammatory hypothesis? Experience with six cases.

Authors:  Humberto Belem de Aquino; Edmur Franco Carelli; Antonio Guilherme Borges Neto; Carlos Umberto Pereira
Journal:  Childs Nerv Syst       Date:  2006-03-09       Impact factor: 1.475

Review 4.  Biomaterials for the central nervous system.

Authors:  Yinghui Zhong; Ravi V Bellamkonda
Journal:  J R Soc Interface       Date:  2008-09-06       Impact factor: 4.118

5.  Development of Microfabricated Magnetic Actuators for Removing Cellular Occlusion.

Authors:  Selene A Lee; Hyowon Lee; James R Pinney; Elvira Khialeeva; Marvin Bergsneider; Jack W Judy
Journal:  J Micromech Microeng       Date:  2011-05       Impact factor: 1.881

6.  Intracranial electrode implantation produces regional neuroinflammation and memory deficits in rats.

Authors:  Yafit Kuttner Hirshler; Uri Polat; Anat Biegon
Journal:  Exp Neurol       Date:  2009-12-21       Impact factor: 5.330

7.  Perforation holes in ventricular catheters--is less more?

Authors:  Ulrich W Thomale; Henning Hosch; Arend Koch; Matthias Schulz; Giesela Stoltenburg; Ernst-Johannes Haberl; Christian Sprung
Journal:  Childs Nerv Syst       Date:  2009-12-19       Impact factor: 1.475

Review 8.  Cerebrospinal Fluid Shunting Complications in Children.

Authors:  Brian W Hanak; Robert H Bonow; Carolyn A Harris; Samuel R Browd
Journal:  Pediatr Neurosurg       Date:  2017-03-02       Impact factor: 1.162

9.  Reduced cell attachment to poly(2-hydroxyethyl methacrylate)-coated ventricular catheters in vitro.

Authors:  Brian W Hanak; Chia-Yun Hsieh; William Donaldson; Samuel R Browd; Kenneth K S Lau; William Shain
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2017-06-20       Impact factor: 3.368

10.  Mitigation of reactive human cell adhesion on poly(dimethylsiloxane) by immobilized trypsin.

Authors:  Anil Kumar H Achyuta; Kyle D Stephens; Hilton G Pryce Lewis; Shashi K Murthy
Journal:  Langmuir       Date:  2010-03-16       Impact factor: 3.882

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.