Literature DB >> 9481492

Infected cardiac pacemaker wires demonstrated by Tc-99m labeled white blood cell scintigraphy.

D M Howarth1, P G Curteis, S Gibson.   

Abstract

Multiple cardiac pacing wires present a potential source of thrombosis and infection within veins and cardiac chambers. A case is presented where persistent infection involved thrombus on cardiac pacing wires in and around the right subclavian and brachiocephalic veins, which proved difficult to localize and treat. Early Ga-67 and Tc-99m labeled white blood cell imaging were negative but, when the latter test was repeated after 5 weeks, the septic focus was identified. Treatment with antibiotic therapy combined with surgical removal of the infected thrombus and both pacing wires was effective in eradicating infection. Failure to demonstrate an infection focus early in the course of the illness may have related to the size of the infection focus; however, in a later phase of the illness, Tc-99m labeled white blood cell imaging proved helpful in localizing focal infection associated with pacemaker wires.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9481492     DOI: 10.1097/00003072-199802000-00002

Source DB:  PubMed          Journal:  Clin Nucl Med        ISSN: 0363-9762            Impact factor:   7.794


  5 in total

1.  A meta-analysis of antibacterial envelope use in prevention of cardiovascular implantable electronic device infection.

Authors:  Sajid Ali; Yousuf Kanjwal; Steven R Bruhl; Mohammed Alo; Mohammed Taleb; Syed S Ali; Ameer Kabour; Owais Khawaja
Journal:  Ther Adv Infect Dis       Date:  2017-05-01

2.  Management of infections involving implanted cardiac electrophysiologic devices.

Authors:  Frédéric L Paulin; Lorne J Gula; Raymond Yee; Allan C Skanes; George J Klein; Andrew D Krahn
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-09

3.  Infected pacemaker causing septic lung emboli detected on FDG PET/CT.

Authors:  Gad Abikhzer; Sophie Turpin; Jean-Luc Bigras
Journal:  J Nucl Cardiol       Date:  2010-06       Impact factor: 5.952

4.  Implantable electrophysiologic cardiac device infections: a risk factor analysis.

Authors:  D Raad; J Irani; E G Akl; S Choueiri; E Azar; J Abboud; C Afif
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2012-08-25       Impact factor: 3.267

5.  Cardiac Implantable Electronic Device Infection in Patients at Risk.

Authors:  Khaldoun G Tarakji; Christopher R Ellis; Pascal Defaye; Charles Kennergren
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-05
  5 in total