Literature DB >> 9481426

Airway response to formaldehyde inhalation in asthmatic subjects with suspected respiratory formaldehyde sensitization.

A Krakowiak1, P Górski, K Pazdrak, U Ruta.   

Abstract

The aim of the study was to characterize the mechanism of formaldehyde (FM)-induced nasal and bronchial response in asthmatic subjects with suspected FM allergy. Ten subjects purported to have FM rhinitis and asthma and 10 healthy subjects submitted to an inhalation provocation in an exposure chamber with FM at a dose of 0.5 mg/m3 over 2 hr. Spirometry at rest and following bronchial provocation with histamine (PC20) were recorded before and after FM inhalation. In addition, FM-specific serum IgE antibodies were measured and cellular, biochemical, and mediator changes were assessed in nasal lavage before, and immediately after, provocation and at 4 hr and 24 hr later. Provocation with FM caused only transient symptoms of rhinitis in both groups. None of the subjects supposed to have occupational asthma developed clinical symptoms of bronchial irritation. No specific IgE antibodies to FM were detected in persons with occupational exposure to FM. No differences in the nasal response to FM were found between subjects reporting to have occupational allergic respiratory diseases and healthy subjects (P > 0.05). In summary, inhaled formaldehyde at a level as low as 0.5 mg/m3 did not induce a specific allergic response either in the upper or in the lower part of the respiratory tract. Moreover, there is no difference in nasal response to FM in asthmatic subjects occupationally exposed to FM and healthy subjects.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9481426     DOI: 10.1002/(sici)1097-0274(199803)33:3<274::aid-ajim9>3.0.co;2-w

Source DB:  PubMed          Journal:  Am J Ind Med        ISSN: 0271-3586            Impact factor:   2.214


  6 in total

1.  Identifying an indoor air exposure limit for formaldehyde considering both irritation and cancer hazards.

Authors:  Robert Golden
Journal:  Crit Rev Toxicol       Date:  2011-06-02       Impact factor: 5.635

2.  Flow cytometric determination of neutrophil respiratory burst activity in workers exposed to formaldehyde.

Authors:  M Lyapina; G Zhelezova; E Petrova; M Boev
Journal:  Int Arch Occup Environ Health       Date:  2004-05-01       Impact factor: 3.015

Review 3.  Recent trend in risk assessment of formaldehyde exposures from indoor air.

Authors:  Gunnar Damgård Nielsen; Søren Thor Larsen; Peder Wolkoff
Journal:  Arch Toxicol       Date:  2012-11-21       Impact factor: 5.153

Review 4.  Assessing exposure to air toxics relative to asthma.

Authors:  Clifford P Weisel
Journal:  Environ Health Perspect       Date:  2002-08       Impact factor: 9.031

5.  Evaluation and application of the RD50 for determining acceptable exposure levels of airborne sensory irritants for the general public.

Authors:  Yu Kuwabara; George V Alexeeff; Rachel Broadwin; Andrew G Salmon
Journal:  Environ Health Perspect       Date:  2007-11       Impact factor: 9.031

6.  Protective role of (Bronco-T) against formaldehyde induced antioxidant, oxidative and histopathological changes in lung of male Wistar rats.

Authors:  Sholapuri Payani; Cherlopalli Mamatha; Chinta Chandraprakash; Matcha Bhaskar
Journal:  Toxicol Rep       Date:  2019-07-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.