Literature DB >> 9479291

Three-dimensional ultrasound imaging. Clinical applications.

A Cusumano1, D J Coleman, R H Silverman, D Z Reinstein, M J Rondeau, R Ursea, S M Daly, H O Lloyd.   

Abstract

OBJECTIVE: The aim of this report is to describe the technology of three-dimensional (3-D) ultrasonic imaging and its impact on improved diagnosis and monitoring of ocular disease.
DESIGN: The authors reviewed techniques for acquiring and displaying 3-D ultrasound data of the eye. PARTICIPANTS: The authors applied these techniques to representative individual cases, including a choroidal hemorrhage, a ciliary body melanoma, a ciliary body detachment, a displaced posterior chamber intraocular lens, and topographic analysis of a normal cornea. INTERVENTION: A computer-controlled motion system was used to perform very high-frequency (VHF) (50-MHz) and conventional (10-MHz) digital 3-D ultrasound data collection. The scanning system allowed digitization of ultrasound data from a series of parallel planes. The 3-D data could be manipulated interactively to obtain two-dimensional images in any plane through the scan volume. The 3-D images were constructed by volume rendering and could be positioned for viewing from a variety of perspectives. The 3-D ultrasound parameter images representing acoustic scatterer properties were generated by spectrum analysis of digitized echo data. Color maps representing the contour and thickness of the epithelium and stroma of the central corneal were generated by digital signal processing of 3-D echo data.
RESULTS: Quantitative volume measurement and biometric techniques enhanced the diagnostic and treatment planning information content in 3-D ultrasound images. The location and extent of hemorrhage and clots within the suprachoroidal space were shown with solid modeling. Volume changes in ciliary body melanoma over time were documented and 3-D ultrasound parameter image changes associated with radiation therapy observed. In ciliary body detachment, the extent of the detachment was shown. Solid modeling of a posterior chamber intraocular lens showed misplacement of the haptic in relation to the lens capsule remnants. Keratopachymetric maps showed the range and variance of thickness and local radius of curvature measurements in the cornea.
CONCLUSIONS: Quantitative volume measurement and biometric tools combined with segmentation of 3-D ultrasound images improve diagnostic and treatment planning informational content of 3-D ultrasound images through improved localization of tissue structures.

Entities:  

Mesh:

Year:  1998        PMID: 9479291     DOI: 10.1016/s0161-6420(98)93211-0

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  10 in total

1.  New applications in ultrasound technology.

Authors:  H R Atta
Journal:  Br J Ophthalmol       Date:  1999-11       Impact factor: 4.638

2.  20 MHz high frequency ultrasound assessment of scleral and intraocular conjunctival squamous cell carcinoma.

Authors:  D H Char; G Kundert; R Bove; J B Crawford
Journal:  Br J Ophthalmol       Date:  2002-06       Impact factor: 4.638

3.  In vivo high-frequency, contrast-enhanced ultrasonography of uveal melanoma in mice: imaging features and histopathologic correlations.

Authors:  Qing Zhang; Hua Yang; Shin J Kang; Yanggan Wang; Geoffrey D Wang; Tonya Coulthard; Hans E Grossniklaus
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-04-01       Impact factor: 4.799

4.  Stromal thickness in the normal cornea: three-dimensional display with artemis very high-frequency digital ultrasound.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2009-09-11       Impact factor: 3.573

5.  SD-OCT analysis of regional epithelial thickness profiles in keratoconus, postoperative corneal ectasia, and normal eyes.

Authors:  Karolinne Maia Rocha; Claudia E Perez-Straziota; E Perez-Straziota; R Doyle Stulting; J Bradley Randleman
Journal:  J Refract Surg       Date:  2013-03       Impact factor: 3.573

6.  Repeatability of layered corneal pachymetry with the artemis very high-frequency digital ultrasound arc-scanner.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2009-11-16       Impact factor: 3.573

7.  In vivo high-frequency contrast-enhanced ultrasonography of choroidal melanoma in rabbits: imaging features and histopathologic correlations.

Authors:  Shin J Kang; Qing Zhang; Samirkumar R Patel; Damian Berezovsky; Hua Yang; Yanggan Wang; Hans E Grossniklaus
Journal:  Br J Ophthalmol       Date:  2013-05-04       Impact factor: 4.638

8.  One-step transepithelial topography-guided ablation in the treatment of myopic astigmatism.

Authors:  Aleksandar Stojanovic; Shihao Chen; Xiangjun Chen; Filip Stojanovic; Jia Zhang; Ting Zhang; Tor Paaske Utheim
Journal:  PLoS One       Date:  2013-06-17       Impact factor: 3.240

9.  Clinical 3D Imaging of the Anterior Segment With Ultrasound Biomicroscopy.

Authors:  Richard W Helms; Ahmed Tahseen Minhaz; David L Wilson; Faruk H Örge
Journal:  Transl Vis Sci Technol       Date:  2021-03-01       Impact factor: 3.283

10.  Applications of epithelial thickness mapping in corneal refractive surgery.

Authors:  Dan Z Reinstein; Timothy J Archer; Ryan S Vida
Journal:  Saudi J Ophthalmol       Date:  2022-07-11
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.