Shaping ability of NT Engine and McXim rotary nickel-titanium instruments in simulated root canals. Part 1.

S A Thompson1, P M Dummer.   

Abstract

The aim of this study was to determine the shaping ability of NT Engine and McXim nickel-titanium rotary instruments in simulated root canals. In all, 40 canals consisting of four different shapes in terms of angle and position of curvature were prepared by a combination of NT Engine and McXim instruments using the technique recommended by the manufacturer. Part 1 of this two-part report describes the efficacy of the instruments in terms of preparation time, instrument failure, canal blockages, loss of canal length and three-dimensional canal form. Overall, the mean preparation time for all canals was 6.01 min, with canal shape having a significant effect (P < 0.01) on the speed of preparation. One instrument fractured and only four instruments deformed, with most of the failures occurring in canals with curves which began 12 mm from the orifice, that is, in short acute curves. None of the canals became blocked with debris. Following preparation, 20 canals retained their original working length but 19 lost length and one gained in length; there were significant differences (P < 0.05) between the canal shapes in terms of mean loss of distance and in the category of distance change. Apical stops as determined from intracanal impressions were present in 37 of the canals; 16 were judged to be of good quality and 21 of poor quality. The canals were found to be smooth in the apical half of the canal in 33 specimens and in the coronal half of 39 specimens. All canals had good taper characteristics and 35 had good flow characteristics. Under the conditions of this study, NT Engine and McXim instruments prepared canals rapidly, with few deformations, no canal blockages and with minimal change in working length. The three-dimensional form of the canals demonstrated good flow and taper characteristics.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9477812     DOI: 10.1046/j.1365-2591.1997.00080.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  2 in total

1.  Comparative evaluation of surface characteristics of dentinal walls with and without using plastic finishing file.

Authors:  Smita Singh; Neeraj Nigam
Journal:  J Conserv Dent       Date:  2010-04

2.  Fracture strength of mesiobuccal roots following canal preparation with hand and rotary instrumentation: an in vitro study.

Authors:  Maryam Zare Jahromi; Parvin Mirzakouchaki; Elnaz Mousavi; Amir Arsalan Navabi
Journal:  Iran Endod J       Date:  2011-08-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.