Literature DB >> 947616

Quality control in haemoglobinometry with special reference to the stability of haemiglobincyanide reference solutions.

O W Van Assendelft, A Buursma, A H Holtz, E J Van Kampen, W G Zijlstra.   

Abstract

In haemoglobinometry grave errors are still being made even though an internationally accepted standardized method is available for the determination of the haemoglobin content of blood. Up to the present only haemiglobincyanide reference solutions have been available on a wide scale to check the measuring stage of the standardized haemiglobincyanide method. These reference solutions are shown to remain stable, under proper storage conditions, for more than 10 years. Concentrated haemoglobin solutions have become available recently, offering the possibility to control the dilution and conversion steps of the haemiglobincyanide method. Such a solution is shown to remain stable, under proper storage conditions, for at least a year. Using both haemiglobincyanide reference solutions and concentrated haemoglobin solutions, as well as having the possibility of checking the cyanide content of the reagent used, an acceptable intra-laboratory control program may now be set up.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 947616     DOI: 10.1016/0009-8981(76)90019-x

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  4 in total

1.  Stability of haemiglobincyanide standards.

Authors:  O W van Assendelft; A Buursma; W G Zijlstra
Journal:  J Clin Pathol       Date:  1996-04       Impact factor: 3.411

2.  Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1995) and specifications for international haemiglobinocyanide standard (4th edition).

Authors:  A Zwart; O W van Assendelft; B S Bull; J M England; S M Lewis; W G Zijlstra
Journal:  J Clin Pathol       Date:  1996-04       Impact factor: 3.411

3.  Carboxyhaemoglobin: a possible reference material for haemoglobin assay.

Authors:  J M Rideout; A Louderback
Journal:  J Clin Pathol       Date:  1982-03       Impact factor: 3.411

4.  International Committee for Standardization in Haematology. Recommendations for reference method for haemoglobinometry in human blood (ICSH standard EP 6/2: 1977) and specifications for international haemiglobincyanide reference preparation (ICSH standard EP 6/3: 1977).

Authors: 
Journal:  J Clin Pathol       Date:  1978-02       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.