Literature DB >> 9473844

Multiple-drug hemodynamic control using fuzzy decision theory.

J W Huang1, R J Roy.   

Abstract

A fuzzy-logic-based, automated drug-delivery system has been developed and validated on a nonlinear canine circulatory model for managing hemodynamic states. This controller features: 1) a fuzzy decision analysis module for patient status determination by assessing cardiac index, systemic vascular resistance index, and pulmonary vascular resistance index and 2) a fuzzy hemodynamic management module utilizing dopamine, phenylephrine, nitroprusside, and nitroglycerin for regulating mean arterial pressure, mean pulmonary arterial pressure, and cardiac output. A rule-based drug delivery scheduling program has been devised and incorporated to execute the therapeutic strategy as recommended by the decision analysis module. Compared to the existing controllers, this system is able to achieve a faster response time with a more secured and effective regulation. The simulation results have demonstrated the feasibility of the decision analysis process for automated management of the arterial and venous circulation with an expanded arsenal of pharmacological agents.

Entities:  

Mesh:

Year:  1998        PMID: 9473844     DOI: 10.1109/10.661269

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

1.  Automatic regulation of hemodynamic variables in acute heart failure by a multiple adaptive predictive controller based on neural networks.

Authors:  Koji Kashihara
Journal:  Ann Biomed Eng       Date:  2006-10-18       Impact factor: 3.934

2.  ASIC design of a digital fuzzy system on chip for medical diagnostic applications.

Authors:  Shubhajit Roy Chowdhury; Aniruddha Roy; Hiranmay Saha
Journal:  J Med Syst       Date:  2009-08-27       Impact factor: 4.460

3.  Accuracy enhancement in a fuzzy expert decision making system through appropriate determination of membership functions and its application in a medical diagnostic decision making system.

Authors:  Suddhasattwa Das; Shubhajit Roy Chowdhury; Hiranmay Saha
Journal:  J Med Syst       Date:  2010-11-24       Impact factor: 4.460

4.  A tool predicting future mean arterial blood pressure values improves the titration of vasoactive drugs.

Authors:  Matthias Görges; Dwayne R Westenskow; Kai Kück; Joseph A Orr
Journal:  J Clin Monit Comput       Date:  2010-06-18       Impact factor: 2.502

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.