Literature DB >> 9473556

Transjugular core liver biopsy with a 19-gauge spring-loaded cutting needle.

J Choh1, B Dolmatch, R Safadi, P Long, M Geisinger, G Lammert, J Dempsey.   

Abstract

One hundred and five sequential transjugular core liver biopsies (TJLBx) were performed in 101 patients with coagulopathy and/or ascites using the 19-gauge Quick-Core Biopsy (QCB) needle. Two-hundred and seventy-three cores were obtained in 295 passes (92. 5%). One-hundred and two of the 105 procedures (97.1%) led to a histopathologic diagnosis. One of the three nondiagnostic biopsies was done because of severe autolysis of the liver. There was one subcapsular hematoma, one hepatic arteriovenous fistula, and one liver capsular puncture. Two minor neck hematomas occurred. One death was reported (unrelated to the procedure). QCB needle TJLBx is an effective and relatively safe way to obtain core liver samples.

Entities:  

Mesh:

Year:  1998        PMID: 9473556     DOI: 10.1007/s002709900220

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  5 in total

1.  Transjugular liver biopsy: how good is it for accurate histological interpretation?

Authors:  E Cholongitas; A Quaglia; D Samonakis; M Senzolo; C Triantos; D Patch; G Leandro; A P Dhillon; A K Burroughs
Journal:  Gut       Date:  2006-04-24       Impact factor: 23.059

2.  Transjugular biopsy of an atypical focal nodular hyperplasia in a patient with acute liver failure clinical presentation.

Authors:  Roberto Miraglia; Luigi Maruzzelli; Marta Ida Minervini; Giuseppe Mamone; Settimo Caruso; Davide Cintorino; Angelo Luca; Bruno Gridelli
Journal:  Emerg Radiol       Date:  2008-05-08

Review 3.  Complications of transjugular biopsies.

Authors:  Rakesh Navuluri; Osman Ahmed
Journal:  Semin Intervent Radiol       Date:  2015-03       Impact factor: 1.513

4.  Two cases of major hemorrhage secondary to transjugular liver biopsy.

Authors:  George E Lynskey; Elliot B Levy; Filip Banovac
Journal:  Semin Intervent Radiol       Date:  2007-09       Impact factor: 1.513

5.  Comparison of a new aspiration needle device and the Quick-Core biopsy needle for transjugular liver biopsy.

Authors:  Toru Ishikawa; Hiroteru Kamimura; Atsunori Tsuchiya; Tadayuki Togashi; Kouji Watanabe; Kei Seki; Hironobu Ohta; Toshiaki Yoshida; Noriko Ishihara; Tomoteru Kamimura
Journal:  World J Gastroenterol       Date:  2006-10-21       Impact factor: 5.742

  5 in total