Literature DB >> 9469546

Comparison of optic disc measurements by Heidelberg Retina Tomograph and manual planimetric techniques.

K Vihanninjoki1, A Tuulonen, R O Burk, P J Airaksinen.   

Abstract

The inner edge of the scleral ring is used as a reference plane for manual, computer assisted optic disc measurements. As it is possible to identify this level with the Heidelberg Retina Tomograph, our aim was to compare manual measurements to those taken with the Heidelberg Retina Tomograph. The material of this pilot study consisted of 12 eyes of 12 patients with early glaucomatous optic disc, retinal nerve fiber layer and/or visual field abnormalities. Measurements of the optic disc and neuroretinal rim area were obtained using our manual planimetric techniques, and the Heidelberg Retina Tomograph. The mean optic disc areas measured smaller with the Heidelberg Retina Tomograph than with the manual techniques (average difference 0.13 mm2; p < 0.05). The neuroretinal rim area measurements and cup-to-disc area ratio using manual and Heidelberg Retina Tomograph techniques did not differ statistically significantly from each other. With the scleral ring as a reference plane, comparable optic disc measurements can be obtained with manual and laser techniques.

Entities:  

Mesh:

Year:  1997        PMID: 9469546     DOI: 10.1111/j.1600-0420.1997.tb00139.x

Source DB:  PubMed          Journal:  Acta Ophthalmol Scand        ISSN: 1395-3907


  4 in total

1.  Evaluation and definition of physiologic macro cups with confocal optic nerve analysis (HRT).

Authors:  E Arenas-Archila; F Caycedo-Yunis; M R Rodríguez
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

2.  Glaucoma diagnosis optic disc analysis comparing Cirrus spectral domain optical coherence tomography and Heidelberg retina tomograph II.

Authors:  Hye Young Shin; Hae-Young Lopilly Park; Kyoung In Jung; Chan Kee Park
Journal:  Jpn J Ophthalmol       Date:  2012-10-27       Impact factor: 2.447

3.  Variability of the normalised rim/disc area quotient estimated by laser scanning tomography. A comparison with conventional planimetry.

Authors:  A S Boros; C P Jonescu-Cuypers; K U Bartz-Schmidt
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

4.  The impact of optic nerve and related characteristics on disc area measurements derived from different imaging techniques.

Authors:  Michael Yapp; George Rennie; Michael P Hennessy; Michael Kalloniatis; Barbara Zangerl
Journal:  PLoS One       Date:  2018-01-17       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.