Comparative push-out test of dense HA implants and HA-coated implants: findings in a canine study.

M Ogiso1, M Yamamura, P T Kuo, D Borgese, T Matsumoto.   

Abstract

Two types of hydroxyapatite (HA) implants have been developed: an HA-coated implant and a dense HA implant. For a longer in situ life span, the HA implant must remain chemically stable and possess high resistance to occlusal force. To determine which type of HA implant shows better durability, this comparative dog study was done to evaluate push-out test results of HA-coated implants and dense HA implants of approximately the same size after implantation in the mandibular and coxal bones for periods ranging from 3 weeks to 10 months. The findings revealed that for the mandibular implants, the push-out values of HA-coated implants were significantly higher than those of dense HA implants at 2 and 4 months after implantation, with significance levels of p < .001 and p < 0.05, respectively. However, there was no significant difference between the two implant types at 10 months. As for the coxal implants, no significant differences were noted for any period. Furthermore, the ratio of push-out values of the dense HA implants to those of the HA-coated implants situated in the same position bilaterally in each bone of the body for each implantation period rose with the passage of time, especially in the mandible. In the mandibular implants, the correlation coefficient of the relationship between the ratio and duration of implantation was highly significant (p < 0.001). Push-out testing caused detachment of the surface portion of the HA coating that was bound to the dense bone from the HA-coated implant at 2, 4, and 10 months after implantation. Furthermore, at 10 months the HA-coated layer in the wide areas of the implants had completely detached from the metal substrate, in contrast to the dense HA implants, which remained durable throughout the test period.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9468044     DOI: 10.1002/(sici)1097-4636(19980305)39:3<364::aid-jbm4>3.0.co;2-h

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  4 in total

1.  Bioactive polymer grafting onto titanium alloy surfaces.

Authors:  A Michiardi; G Hélary; P-C T Nguyen; L J Gamble; F Anagnostou; D G Castner; V Migonney
Journal:  Acta Biomater       Date:  2009-09-04       Impact factor: 8.947

2.  Bone response to porous alumina implants coated with bioactive materials, observed using different characterization techniques.

Authors:  Claudia C Camilo; Celey A E Silveira; Rafael S Faeda; João M D de Almeida Rollo; Benedito de Moraes Purquerio; Carlos Alberto Fortulan
Journal:  J Appl Biomater Funct Mater       Date:  2017-07-27       Impact factor: 2.604

Review 3.  Endosseous Dental Implant Materials and Clinical Outcomes of Different Alloys: A Systematic Review.

Authors:  Luca Fiorillo; Marco Cicciù; Tolga Fikret Tozum; Matteo Saccucci; Cristiano Orlando; Giovanni Luca Romano; Cesare D'Amico; Gabriele Cervino
Journal:  Materials (Basel)       Date:  2022-03-07       Impact factor: 3.623

4.  Application of calcium phosphate materials in dentistry.

Authors:  Jabr S Al-Sanabani; Ahmed A Madfa; Fadhel A Al-Sanabani
Journal:  Int J Biomater       Date:  2013-06-26