A comparison of the accuracy and reproducibility of digital three-dimensional coronary artery reconstructions using edge detection or videodensitometry.

J B Muhlestein1, Q Zhang, D J Parker, S D Horn, D L Parker, J L Anderson.   

Abstract

Global quantitative three-dimensional measurements of coronary arteries may be helpful in determining the functional significance of various forms of coronary pathology. A computerized system has been developed that is capable of performing 3-D reconstruction of digitized images obtained from multiple coronary angiographic views using either automated edge detection (AED) or videodensitometric (VD) techniques. To compare the accuracy and reproducibility of measurements obtained from this system using either technique, stationary and moving coronary aluminum 3-D phantoms, each with 13 branches (diameter 0.58-6.35 mm, length 21.5-64.5 mm), were imaged and reconstructed 10 separate times each. Individual branch lengths and diameters were calculated and compared to each other and to known values. Diameter measurements were compared using either AED or VD. Intraclass correlation coefficients between observed values (ICC) for vessel length were r = 0.89 for the stationary and r = 0.97 for the moving phantom. ICCs for vessel diameter were r = 0.93 (AED) and r = 0.95 (VD) for the stationary and r = 0.98 (AED) and r = 0.97 (VD) for the moving phantom. Mean differences (+/-SD) between true and observed values [MDTO(+/-SD)] for vessel length were -1.0 +/- 3.9 mm for the stationary and -3.5 +/- 3.2 mm for the moving phantom. MDTO(+/-SD) for vessel diameter were -0.10 +/- 0.52 mm (AED) and +0.03 +/- 0.30 mm (VD) for the stationary and -0.21 +/- 0. 44 mm (AED) and -0.12 +/- 0.33 (VD) for the moving phantom. We conclude that the quantitative accuracy and reproducibility of measurements obtained by computerized 3-D reconstruction of coronary model phantoms is of high enough quality to warrant further clinical evaluation. VD appears to be more accurate than AED for measuring vessel diameter. Copyright 1997 Academic Press.

Mesh:

Substances:

Year:  1997        PMID: 9466833     DOI: 10.1006/cbmr.1997.1453

Source DB:  PubMed          Journal:  Comput Biomed Res        ISSN: 0010-4809


  2 in total

1.  Validation of an accurate method for three-dimensional reconstruction and quantitative assessment of volumes, lengths and diameters of coronary vascular branches and segments from biplane angiographic projections.

Authors:  E Wellnhofer; A Wahle; I Mugaragu; J Gross; H Oswald; E Fleck
Journal:  Int J Card Imaging       Date:  1999-10

2.  3D coronary reconstruction from routine single-plane coronary angiograms: clinical validation and quantitative analysis of the right coronary artery in 100 patients.

Authors:  J C Messenger; S Y Chen; J D Carroll; J E Burchenal; K Kioussopoulos; B M Groves
Journal:  Int J Card Imaging       Date:  2000-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.