Literature DB >> 9465951

[Contrast media enhanced magnetic resonance angiography for determining patency of a coronary bypass. A comparison with coronary angiography].

B J Wintersperger1, A von Smekal, M G Engelmann, A Knez, H V Penzkofer, G Laub, M Reiser.   

Abstract

AIM: Assessment of graft patency with current non-invasive MRA techniques is particularly difficult for evaluating internal mammary artery grafts. Our aim is to determine the accuracy of a contrast enhanced MRA technique is assessing graft patency.
METHODS: We examined 19 patients with a total of 53 grafts (32 venous/21 arterial), using an ultrafast contrast enhanced 3D gradient-echo technique and compared this with the results of selective angiography.
RESULTS: Sensitivity of the contrast enhanced method was 95.2% for venous grafts, 94.4% for IMA grafts and 94.8% overall. Specificity was 85.7% overall, 90.9% for venous and 66.7% for IMA grafts. Positive predictive value was 94.4%.
CONCLUSION: Compared with previous studies, visualisation of IMA grafts was improved by using contrast enhanced MRA. In this preliminary study, contrast enhanced MRA proved promising for the assessment of graft patency.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9465951     DOI: 10.1055/s-2007-1015585

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  3 in total

1.  Non-invasive magnetic resonance imaging of coronary bypass grafts. comparison of the haste- and navigator techniques with conventional coronary angiography.

Authors:  Th Wittlinger; T Voigtländer; K F Kreitner; P Kalden; M Thelen; J Meyer
Journal:  Int J Cardiovasc Imaging       Date:  2002-12       Impact factor: 2.357

Review 2.  Contribution of cardiovascular magnetic resonance in the evaluation of coronary arteries.

Authors:  Sophie Mavrogeni; George Markousis-Mavrogenis; Genovefa Kolovou
Journal:  World J Cardiol       Date:  2014-10-26

Review 3.  Magnetic resonance coronary angiography: where are we today?

Authors:  Amedeo Chiribiri; Rene M Botnar; Eike Nagel
Journal:  Curr Cardiol Rep       Date:  2013-02       Impact factor: 2.931