Literature DB >> 9463959

Effect of sample volume on quantitative analysis by solid-phase microextraction. Part 1. Theoretical considerations.

T Górecki1, J Pawliszyn.   

Abstract

This paper discusses the effect of sample volume on the amount of analyte extracted from a sample by solid-phase microextraction (SPME) in two-phase (sample-fiber coating) and three-phase (sample-headspace-fiber coating) systems. Up-to-date knowledge is summarized, and new concepts are introduced. The effect of sample volume on quantification and precision of results can be neglected only in rare cases. The minimum sample volume which ensures that the amount extracted, n, is lower than 1% of the initial amount of the analyte present in the sample, as well as the volume for which exactly half of the initial amount of the analyte is extracted, have been calculated for both two- and three-phase systems. It is critical that the volumes of samples and standards are the same during analysis by SPME. Extraction kinetics in headspace analysis is dependent on the headspace capacity. If it is sufficiently large, the analyte is extracted almost exclusively from the gaseous phase, and equilibration can be very fast. On the other hand, this causes a significant loss of sensitivity. The effect of sample volume on the determination of the value of the partition coefficient, K, is also discussed. If the change in concentration of the analyte in the sample at equilibrium is not taken into account, erroneous results are obtained. Even when a proper procedure is used, there are practical limitations to the accuracy of the K value determination. Large sample volumes should always be used for K value determination, as they enable broader ranges of K values to be covered with good accuracy.

Mesh:

Year:  1997        PMID: 9463959     DOI: 10.1039/a701303e

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  5 in total

1.  Direct detection of benzene, toluene, and ethylbenzene at trace levels in ambient air by atmospheric pressure chemical ionization using a handheld mass spectrometer.

Authors:  Guangming Huang; Liang Gao; Jason Duncan; Jason D Harper; Nathaniel L Sanders; Zheng Ouyang; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2009-09-30       Impact factor: 3.109

2.  Determination of total and available fractions of PAHs by SPME in oily wastewaters: overcoming interference from NAPL and NOM.

Authors:  Rui B Gomes; Regina Nogueira; José M Oliveira; João Peixoto; António G Brito
Journal:  Environ Sci Pollut Res Int       Date:  2009-03-17       Impact factor: 4.223

3.  Sustained release ketamine-loaded porous silicon-PLGA microparticles prepared by an optimized supercritical CO2 process.

Authors:  Weizhi Xu; Zonglan Zhao; James Falconer; Andrew K Whittaker; Amirali Popat; Maree T Smith; Tushar Kumeria; Felicity Y Han
Journal:  Drug Deliv Transl Res       Date:  2021-04-28       Impact factor: 4.617

Review 4.  Advanced Solid-Phase Microextraction Techniques and Related Automation: A Review of Commercially Available Technologies.

Authors:  Stefano Dugheri; Nicola Mucci; Giovanni Cappelli; Lucia Trevisani; Alessandro Bonari; Elisabetta Bucaletti; Donato Squillaci; Giulio Arcangeli
Journal:  J Anal Methods Chem       Date:  2022-02-04       Impact factor: 2.193

5.  Interlaboratory Comparison of a Biomimetic Extraction Method Applied to Oil Sands Process-Affected Waters.

Authors:  Daniel J Letinski; Asfaw Bekele; Martin J Connelly
Journal:  Environ Toxicol Chem       Date:  2022-07       Impact factor: 4.218

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.