Assessing baroreflex sensitivity in post-myocardial infarction patients: comparison of spectral and phenylephrine techniques.

R Maestri1, G D Pinna, A Mortara, M T La Rovere, L Tavazzi.   

Abstract

OBJECTIVES: This study sought to compare, in post-myocardial infarction patients, baroreflex sensitivity (BRS) measured by the phenylephrine method (Phe-BRS) with that estimated by the Robbe (Robbe-BRS) and Pagani (alpha-low frequency [LF] and alpha-high frequency [HF]) spectral techniques.
BACKGROUND: BRS assessed by Phe-BRS has been shown to be of prognostic value in patients with a previous myocardial infarction, but the need for drug injection limits the use of this technique. Several noninvasive methods based on spectral analysis of systolic arterial pressure and heart period have been proposed, but their agreement with Phe-BRS has never been investigated in post-myocardial infarction patients.
METHODS: The linear association and the agreement between each spectral measurement and Phe-BRS were assessed by correlation analysis and by computing the relative bias and the limits of agreement in 51 post-myocardial infarction patients.
RESULTS: The correlation with Phe-BRS was r = 0.63 for Robbe-BRS, r = 0.62 for alpha-LF and r = 0.59 for alpha-HF. The relative bias was significant for alpha-LF (2.6 ms/mm Hg, p < 0.001) and alpha-HF (2.5 ms/mm Hg, p = 0.01) and not significant (-0.6 ms/mm Hg, p = 0.3) for Robbe-BRS. The normalized limits of agreement ranged from -98% to 95% for Robbe-BRS, from -67% to 126% for alpha-LF and from -108% to 143% for alpha-HF. When patients were classified according to left ventricular ejection fraction (LVEF, cutoff value 40%), the relative bias was higher in patients with a depressed LVEF, although statistical significance was high only for Robbe-BRS and was borderline for alpha-LF. The limits of agreement were similar in both groups of patients (p > 0.3).
CONCLUSIONS: Despite a substantial linear association, the agreement between spectral measurements and Phe-BRS in post-myocardial infarction patients is weak because the difference can be as large as the BRS value being estimated. Phe-BRS is the measurement most associated with hemodynamic impairment. Because several factors within each method contribute to the overall difference, neither method can be defined as being better than the other in estimating baroreflex gain, nor can one be used as an alternative to the other. Ad hoc studies are needed to assess which method provides the most useful physiologic or pathophysiologic information or the most accurate prediction of prognosis.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9462578     DOI: 10.1016/s0735-1097(97)00499-3

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  14 in total

1.  New method to measure and improve consistency of baroreflex sensitivity values.

Authors:  Luciano Bernardi; Giacomo De Barbieri; Milla Rosengård-Bärlund; Ville-Petteri Mäkinen; Cesare Porta; Per-Henrik Groop
Journal:  Clin Auton Res       Date:  2010-08-12       Impact factor: 4.435

Review 2.  Baroreflex sensitivity: measurement and clinical implications.

Authors:  Maria Teresa La Rovere; Gian Domenico Pinna; Grzegorz Raczak
Journal:  Ann Noninvasive Electrocardiol       Date:  2008-04       Impact factor: 1.468

3.  Cardiovagal autonomic function in sedentary and trained offspring of hypertensive parents.

Authors:  Zsuzsanna Lénárd; Péter Studinger; Beatrix Mersich; Gábor Pavlik; Mark Kollai
Journal:  J Physiol       Date:  2005-03-17       Impact factor: 5.182

4.  Positive end-expiratory pressure may alter breathing cardiovascular variability and baroreflex gain in mechanically ventilated patients.

Authors:  Andry Van de Louw; Claire Médigue; Yves Papelier; François Cottin
Journal:  Respir Res       Date:  2010-04-19

5.  A comparison of pharmacologic and spontaneous baroreflex methods in aging and hypertension.

Authors:  Milos Milic; Ping Sun; Fujun Liu; Claudia Fainman; Joel Dimsdale; Paul J Mills; Michael G Ziegler
Journal:  J Hypertens       Date:  2009-06       Impact factor: 4.844

6.  Immediate and Complex Cardiovascular Adaptation to an Acute Alcohol Dose.

Authors:  Jennifer F Buckman; David Eddie; Evgeny G Vaschillo; Bronya Vaschillo; Aaron Garcia; Marsha E Bates
Journal:  Alcohol Clin Exp Res       Date:  2015-11-28       Impact factor: 3.928

7.  High sugar intake exacerbates cardiac reperfusion injury in perinatal taurine depleted adult rats.

Authors:  Supaporn Kulthinee; J Michael Wyss; Dusit Jirakulsomchok; Sanya Roysommuti
Journal:  J Biomed Sci       Date:  2010-08-24       Impact factor: 8.410

8.  Determination of baroreflex sensitivity during the modified Oxford maneuver by trigonometric regressive spectral analysis.

Authors:  Julia Gasch; Manja Reimann; Heinz Reichmann; Heinz Rüdiger; Tjalf Ziemssen
Journal:  PLoS One       Date:  2011-03-18       Impact factor: 3.240

9.  Impact and management of physiological calibration in spectral analysis of blood pressure variability.

Authors:  Antti M Kiviniemi; Heidi Hintsala; Arto J Hautala; Tiina M Ikäheimo; Jouni J Jaakkola; Suvi Tiinanen; Tapio Seppänen; Mikko P Tulppo
Journal:  Front Physiol       Date:  2014-12-03       Impact factor: 4.566

10.  Effect of oral glucocorticoid intake on autonomic cardiovascular control.

Authors:  F Cottin; V Malcurat; H Zorgati; F Prieur; Z Labsy; M C Do; O Gagey; K Collomp
Journal:  Springerplus       Date:  2015-10-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.