Literature DB >> 9460160

Mechanical stability of the AO internal spinal fixation system compared with that of the Hartshill rectangle and sublaminar wiring in the management of unstable burst fractures of the thoracic and lumbar spine.

T R Cresswell1, P D Marshall, R B Smith.   

Abstract

STUDY
DESIGN: A radiographic comparison of the mechanical efficacy of the Hartshill rectangle and that of the AO internal spinal skeletal fixation systems in the management of unstable burst fractures of the thoracic and lumbar spine.
OBJECTIVES: To study the restoration and maintenance of normal spinal anatomy after open reduction and internal fixation of unstable burst fractures of the thoracic and lumbar spine. SUMMARY OF BACKGROUND DATA: There are laboratory studies documenting the biomechanical advantages of the AO internal spinal skeletal fixation systems. There have been no previous comparisons of the internal spinal skeletal fixation system with the Hartshill rectangle and sublaminar wiring in matched patient groups.
METHODS: Radiographs obtained before surgery, immediately after surgery, and at 2 years after surgery were used to assess the restoration and maintenance of normal spinal anatomy in 14 patients who had undergone stabilization with the Hartshill System and in 12 patients who had undergone internal fixation using the AO internal spinal skeletal fixation system.
RESULTS: The initial restoration of normal spinal anatomy was good using both systems. However, on examination 2 years after surgery, it was found that the AO system provided significantly superior maintenance of both middle (P < 0.01) and anterior column anatomy (P < 0.001).
CONCLUSION: The AO internal spinal skeletal fixation systems is associated with significantly superior maintenance of spinal anatomy 2 years after surgery.

Entities:  

Mesh:

Year:  1998        PMID: 9460160     DOI: 10.1097/00007632-199801010-00022

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  7 in total

Review 1.  Anterior versus posterior approach for treatment of thoracolumbar burst fractures: a meta-analysis.

Authors:  Gui Jun Xu; Zhi Jun Li; Jian Xiong Ma; Tao Zhang; Xin Fu; Xin Long Ma
Journal:  Eur Spine J       Date:  2013-09-07       Impact factor: 3.134

2.  Short segment pedicle screw instrumentation and augmentation vertebroplasty in lumbar burst fractures: an experience.

Authors:  Suhail Afzal; Saleem Akbar; Shabir A Dhar
Journal:  Eur Spine J       Date:  2008-01-12       Impact factor: 3.134

3.  Improved Monosegment Pedicle Instrumentation for Treatment of Thoracolumbar Incomplete Burst Fractures.

Authors:  Liehua Liu; Yibo Gan; Qiang Zhou; Haoming Wang; Fei Dai; Fei Luo; Tianyong Hou; Chengmin Zhang; Chen Zhao; Jinsong Zhang; Jianzhong Xu; Yingwen Lü
Journal:  Biomed Res Int       Date:  2015-05-04       Impact factor: 3.411

4.  Minimally invasive pedicle screw fixation combined with percutaneous vertebroplasty for preventing secondary fracture after vertebroplasty.

Authors:  Yu-Tong Gu; Dong-Hui Zhu; Hai-Fei Liu; Feng Zhang; Robert McGuire
Journal:  J Orthop Surg Res       Date:  2015-03-07       Impact factor: 2.359

5.  Thoracolumbar burst fracture with complete paraplegia: rationale for second-stage anterior decompression and fusion regarding functional outcome.

Authors:  Mukund M Prabhakar; Bhagwat Singh Rao; Lilam Patel
Journal:  J Orthop Traumatol       Date:  2009-05-26

6.  Safety and efficacy of spinal loop rectangle and sublaminar wires for osteoporotic vertebral compression fracture fixation.

Authors:  Sanganagouda Shivanagouda Patil; Shekhar Yashwant Bhojaraj; Abhay Madhusudan Nene
Journal:  Asian J Neurosurg       Date:  2017 Jul-Sep

7.  Single-Stage Posterior Vertebral Column Resection With Circumferential Reconstruction for Thoracic/Thoracolumbar Burst Fractures With or Without Neurological Deficit: Clinical Neurological and Radiological Outcomes.

Authors:  Azmi Hamzaoglu; Mustafa Elsadig; Selhan Karadereler; Ayhan Mutlu; Yunus Emre Akman; Huseyin Ozturk; Okan Aslantürk; Tunay Sanlı; Sinan Kahraman; Meric Enercan
Journal:  Global Spine J       Date:  2020-10-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.