Literature DB >> 9460115

Interactive three-dimensional volume rendering of spiral CT data: current applications in the thorax.

P T Johnson1, E K Fishman, J R Duckwall, P S Calhoun, D G Heath.   

Abstract

Spiral computed tomographic (CT) data sets coupled with a real-time volume-rendering technique allow creation of accurate three-dimensional (3D) images that can be used for a wide range of clinical applications. The image contrast of and relative pixel attenuations in the final image can be interactively modified by the user in real time by manipulating trapezoidal transfer functions. Although 3D images are not required for diagnosis, they aid both radiologists and referring clinicians by demonstrating anatomic relationships and the extent of disease, particularly for vessels oriented in the z axis. Three-dimensional imaging of the vasculature and airway structures has many advantages, including the potential to obviate invasive procedures such as angiography and bronchoscopy. Clinical applications of volume rendering of spiral CT data include cardiovascular imaging (aorta, pulmonary vasculature, and venous abnormalities), staging of thoracic neoplasms (mediastinal and pulmonary masses), tracheobronchial imaging, and imaging of chest wall disease.

Entities:  

Mesh:

Year:  1998        PMID: 9460115     DOI: 10.1148/radiographics.18.1.9460115

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  6 in total

1.  Technologies for image distribution in hospitals.

Authors:  Elmar Kotter; Tobias Baumann; Dieter Jäger; Mathias Langer
Journal:  Eur Radiol       Date:  2006-03-10       Impact factor: 5.315

2.  Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

Authors:  David E Rosow; Dushyant Sahani; Oliver Strobel; Sanjeeva Kalva; Mari Mino-Kenudson; Nagaraj S Holalkere; Guido Alsfasser; Sanjay Saini; Susanna I Lee; Peter R Mueller; Carlos Fernández-del Castillo; Andrew L Warshaw; Sarah P Thayer
Journal:  J Gastrointest Surg       Date:  2005-12       Impact factor: 3.452

3.  Real-time volume rendering of MRCP: clinical applications.

Authors:  E Neri; P Boraschi; D Caramella; G Braccini; R Gigoni; M Cosottini; S Lodovigi; C Bartolozzi
Journal:  MAGMA       Date:  2000-02       Impact factor: 2.310

4.  Feasibility of assessing pulmonary blood volume using C-arm CT during transpulmonary chemoperfusion and chemoembolization in primary and secondary lung tumours.

Authors:  Thomas J Vogl; Nour-Eldin A Nour-Eldin; Nagy N N Naguib; Thomas Lehnert; Hanns Ackermann; Renate Hammerstingl; Marcus Hezel
Journal:  Br J Radiol       Date:  2016-04-05       Impact factor: 3.039

5.  Intralobar pulmonary sequestration in elderly woman: a rare case report with emphasis on imaging findings.

Authors:  Qays Ahmed Hassan Al-Timimy; Hind Fadhil Al-Shamseei
Journal:  Radiol Case Rep       Date:  2016-06-22

6.  Evaluation of pulmonary sequestration with multidetector computed tomography angiography in a select cohort of patients: A retrospective study.

Authors:  Qihua Long; Yunfei Zha; Zhigang Yang
Journal:  Clinics (Sao Paulo)       Date:  2016-07       Impact factor: 2.365

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.