This ex-vivo study compared the static frictional resistance of three self-ligating brackets with a conventional steel-ligated Ultratrimm bracket. The effects of archwire size (0.020, 0.019 x 0.025 and 0.021 x 0.025-inch), bracket/archwire angulation (0, 5 and 10 degrees) and the presence of unstimulated human saliva were investigated. The study demonstrated that both increases in wire size and bracket/archwire angulation resulted in increased static frictional resistance for all bracket types tested, with the presence of saliva having an inconsistent effect. Mobil-Lock Variable-Slot had the least friction for all wires for 0 degree angulation. However, with the introduction of angulation, the values were comparable to those of the other brackets. Activa brackets had the second lowest frictional resistance, although high values were found with 0.019 x 0.025-inch wires. SPEED brackets demonstrated low forces with round wires, although with rectangular wires or in the presence of angulation, friction was greatly increased. Ultratrimm brackets produced large individual variation, confirming the difficulty in standardizing ligation force, although under certain conditions, significantly larger frictional forces were observed. In conclusion, self-ligating brackets showed reduced frictional resistance in comparison to steel ligated brackets only under certain conditions.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9459030     DOI: 10.1093/ortho/24.4.309

Source DB:  PubMed          Journal:  Br J Orthod        ISSN: 0301-228X


  28 in total

1.  Comparative evaluation of anchorage loss between self-ligating appliance and Conventional pre-adjusted edgewise appliance using sliding mechanics - A retrospective study.

Authors:  Pankaj Juneja; G Shivaprakash; S S Chopra; P B Kambalyal
Journal:  Med J Armed Forces India       Date:  2014-04-03

2.  Plaque retention on elastomeric ligatures. An in vivo study.

Authors:  R Condò; A Casaglia; S G Condò; L Cerroni
Journal:  Oral Implantol (Rome)       Date:  2013-03-19

3.  Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires.

Authors:  Vanessa Vieira Leite; Murilo Baena Lopes; Alcides Gonini Júnior; Marcio Rodrigues de Almeida; Sandra Kiss Moura; Renato Rodrigues de Almeida
Journal:  Dental Press J Orthod       Date:  2014 May-Jun

4.  Friction behavior of self-ligating and conventional brackets with different ligature systems.

Authors:  Alexandra Szczupakowski; Susanne Reimann; Cornelius Dirk; Ludger Keilig; Anna Weber; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-05-24       Impact factor: 1.938

5.  Effect of archwire qualities and bracket designs on the force systems during leveling of malaligned teeth.

Authors:  W Perrey; A Konermann; L Keilig; S Reimann; A Jäger; C Bourauel
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

Review 6.  Systematic review on self-ligating vs. conventional brackets: initial pain, number of visits, treatment time.

Authors:  Ales Čelar; Magdalena Schedlberger; Petra Dörfler; Michael Bertl
Journal:  J Orofac Orthop       Date:  2013-01-10       Impact factor: 1.938

7.  Influence of thermal or chemical degradation on the frictional force of an experimental coated NiTi wire.

Authors:  Ana Maria Bezerra Bandeira; Marcia Pereira Alves dos Santos; Gino Pulitini; Carlos Nelson Elias; Marysilva Ferreira da Costa
Journal:  Angle Orthod       Date:  2011-02-07       Impact factor: 2.079

8.  Friction properties according to vertical and horizontal tooth displacement and bracket type during initial leveling and alignment.

Authors:  Wook Heo; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2011-02-09       Impact factor: 2.079

9.  The leveling effectiveness of self-ligating and conventional brackets for complex tooth malalignments.

Authors:  Magali Fansa; Ludger Keilig; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2009-08-02       Impact factor: 1.938

10.  Orthodontic treatment efficiency with self-ligating and conventional edgewise twin brackets: a prospective randomized clinical trial.

Authors:  Kristina Johansson; Fredrik Lundström
Journal:  Angle Orthod       Date:  2012-03-07       Impact factor: 2.079