| Literature DB >> 9456139 |
H T Henneveld1, P Hutter, F J Hitchcock, N Sreeram.
Abstract
Transcatheter fenestration and balloon dilation of an atrial baffle created from native atrial tissue was attempted in a 15-year-old girl with failing Fontan physiology and protein-losing enteropathy. After transseptal puncture, initial dilations with a 10-mm and 12-mm diameter balloon resulted in an inadequate fenestration, with no significant decrease of right atrial pressure or systemic arterial saturation. Dilation of the fenestration with a 16-mm-diameter balloon produced a tear of the atrial septum and subsequent death. Balloon dilation of native atrial tissue may result in uncontrolled tears of the atrial septum.Entities:
Mesh:
Year: 1998 PMID: 9456139 DOI: 10.1016/s0003-4975(97)01265-4
Source DB: PubMed Journal: Ann Thorac Surg ISSN: 0003-4975 Impact factor: 4.330