Literature DB >> 9449566

High-performance liquid chromatographic assay for the quantitation of irbesartan (SR 47436/BMS-186295) in human plasma and urine.

S Y Chang1, D B Whigan, N N Vachharajani, R Patel.   

Abstract

A selective, accurate, precise and reproducible high-performance liquid chromatographic assay was developed for the quantitation of irbesartan, an angiotensin II antagonist, in human plasma and urine samples. The method involved solid-phase extraction of irbesartan and internal standard (I.S.) using a 100-mg Isolute CN cartridge. A portion of the eluate was injected onto an ODS analytical column connected to a fluorescence detector that was set at an excitation wavelength of 250 nm and an emission wavelength of 371 nm. The mobile phase consisted of 50% acetonitrile and a 50% weak phosphate-triethylamine solution, pH 3.5, at a flow-rate of 0.8 ml/min. The assay was linear from 1 to 1000 ng/ml with both plasma and urine. In either matrix, the lower limit of quantitation was 1 ng/ml. The analyses of quality control samples indicated that the nominal values could be predicted with an accuracy >95%. The inter- and intra-day coefficients of variation for the analyses in both matrices were <8%. Irbesartan was stable in both human plasma and urine for at least seven months at -20 degrees C. The application of the assay to a pharmacokinetic study is described.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9449566     DOI: 10.1016/s0378-4347(97)00387-3

Source DB:  PubMed          Journal:  J Chromatogr B Biomed Sci Appl        ISSN: 1387-2273


  4 in total

1.  The effects of age and gender on the pharmacokinetics of irbesartan.

Authors:  N N Vachharajani; W C Shyu; R A Smith; D S Greene
Journal:  Br J Clin Pharmacol       Date:  1998-12       Impact factor: 4.335

2.  Novel and validated titrimetric method for determination of selected angiotensin-II-receptor antagonists in pharmaceutical preparations and its comparison with UV spectrophotometric determination.

Authors:  Shrikant H Patil; Minakshi V Janjale
Journal:  J Pharm Anal       Date:  2012-04-09

3.  A validated stability indicating HPTLC method for simultaneous estimation of irbesartan and hydrochlorothiazide.

Authors:  Amol S Khodke; Laxman V Potale; Mrinalini C Damle; Kailash G Bothara
Journal:  Pharm Methods       Date:  2010-10

4.  New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma.

Authors:  Tanveer A Wani; Seema Zargar
Journal:  J Food Drug Anal       Date:  2015-03-26       Impact factor: 6.157

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.