Observer agreement in the assessment of mandibular trabecular bone pattern from panoramic radiographs.

A Taguchi1, K Tanimoto, Y Suei, K Otani, M Wadamoto, Y Akagawa, T Wada, M Rohlin.   

Abstract

OBJECTIVES: To study the observer agreement in the assessment of trabecular pattern of the mandible from panoramic radiographs.
METHODS: Seven observers were asked to classify the trabecular pattern of 100 edentulous regions of the mandible in 80 randomly selected panoramic radiographs into one of five grades with the aid of a written description and reference images. Intra- and interobserver agreement was calculated as overall agreement and Kappa index.
RESULTS: The intra-observer agreement varied between 65% and 79%. The Kappa index for intra-observer agreement was moderate for three observers and substantial for four. For all seven observers, it varied according to the grade of trabecular bone pattern, but the majority deviated from each other by only one grade.
CONCLUSION: The relatively high rates of observer agreement indicate that panoramic radiography can be used for the clinical assessment of the trabecular pattern of the mandible.

Mesh:

Year:  1997        PMID: 9442623     DOI: 10.1038/sj.dmfr.4600213

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  1 in total

1.  Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions.

Authors:  Sima Nikneshan; Mohamad Sharafi; Naghmeh Emadi
Journal:  Imaging Sci Dent       Date:  2013-09-23
  1 in total