| Literature DB >> 94337 |
L S Weiner, J T Howell, M P Langford, G J Stanton, S Baron, R M Goldblum, R A Lord, A S Goldman.
Abstract
The effects of specific antibodies in chronic echovirus type 5 (echo 5) encephalitis were investigated in a patient with x-linked hypogammaglobulinemia. Virus was detected in cerebrospinal fluid (CSF) and blood despite treatment with commercial human gammaglobulin that contained low titers of antibodies to echo 5 (0.6 x 10(4) units per injection). Virus disappeared from blood and CSF when plasma containing high concentrations of antibodies (total dose, 1--4 x 10(4) units/kg) was administered intravenously. Maximal inhibition of virus was achieved in culture and in the patient's CSF when the titer of antibody to echo 5 in CSF was greater than or equal to 16 units/ml. Although the patient died, hyperimmune plasma improved the neurologic status and eliminated detectable virus from the blood and CSF.Entities:
Mesh:
Substances:
Year: 1979 PMID: 94337 DOI: 10.1093/infdis/140.6.858
Source DB: PubMed Journal: J Infect Dis ISSN: 0022-1899 Impact factor: 5.226