Literature DB >> 9430307

Removal of an infected silicone rod frontalis sling without recurrence of ptosis.

J P Green1, T Wojno.   

Abstract

We examined a child with congenital ptosis. She underwent a bilateral silicone rod frontalis sling operation. One of the slings became infected and necessitated removal. We noticed no recurrence of her ptosis after sling removal. Removal of a frontalis sling does not invariably lead to recurrence of ptosis. We hypothesize that a scar tract formed in the plane of tissue from which the sling was removed. This band of scar tissue can act as a frontalis sling to elevate the eyelid.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9430307     DOI: 10.1097/00002341-199712000-00010

Source DB:  PubMed          Journal:  Ophthalmic Plast Reconstr Surg        ISSN: 0740-9303            Impact factor:   1.746


  1 in total

1.  Segmental removal of infected frontalis sling.

Authors:  Snehaa Maripudi; Francis Lawson Grumbine; Shannath Merbs; Janet Leath Alexander
Journal:  Digit J Ophthalmol       Date:  2021-11-14
  1 in total