Literature DB >> 9429341

Evaluation of mean skin temperature formulas by infrared thermography.

J K Choi1, K Miki, S Sagawa, K Shiraki.   

Abstract

To study the reliability of formulas for calculating mean skin temperature (Tsk), values were computed by 18 different techniques and were compared with the mean of 10,841 skin temperatures measured by infrared thermography. One hundred whole-body infrared thermograms were scanned in ten resting males while changing the air temperature from 40 degrees C to 4 degrees C. Local, regional average and mean skin temperatures were obtained using an image processing system. The agreement frequency, defined as the percentage of the calculated Tsk values which agreed with the corresponding infrared thermographic Tsk within +/- 0.2 degree C, ranged for with the various formulas from 7% to 80%. In many sites, the local skin temperature did not coincide with the regional average skin temperature. When the local skin temperatures which showed the highest percentage similarity to the regional average skin temperature within +/- 0.4 degree C were applied to the formula, the agreement frequency was markedly improved for all formulas. However, the agreement frequency was not affected by changing the weighting factors from specific constants to individually measured values of regional surface area. By applying the physiologically reliable accuracy range of +/- 0.2 degree C in the moderate and +/- 0.4 degree C in the cool condition, agreement frequencies of at least 95% were observed in formulas involving seven or more skin temperature measurement sites, including the hand and foot. We conclude that calculation of a reliable mean skin temperature must involve more than seven skin temperature measurement sites regardless of ambient temperature. Optimal sites for skin temperature measurement are proposed for various formulas.

Entities:  

Mesh:

Year:  1997        PMID: 9429341     DOI: 10.1007/s004840050056

Source DB:  PubMed          Journal:  Int J Biometeorol        ISSN: 0020-7128            Impact factor:   3.787


  15 in total

1.  Effect of uniform and non-uniform skin temperature on thermal exchanges in water in humans.

Authors:  Jang Kyu Choi; Hye Sook Lee; Yang Saeng Park; Keizo Shiraki
Journal:  Int J Biometeorol       Date:  2002-12-11       Impact factor: 3.787

2.  Assessment of body mapping sportswear using a manikin operated in constant temperature mode and thermoregulatory model control mode.

Authors:  Faming Wang; Simona Del Ferraro; Vincenzo Molinaro; Matthew Morrissey; René Rossi
Journal:  Int J Biometeorol       Date:  2013-12-20       Impact factor: 3.787

Review 3.  Sensors Capabilities, Performance, and Use of Consumer Sleep Technology.

Authors:  Massimiliano de Zambotti; Nicola Cellini; Luca Menghini; Michela Sarlo; Fiona C Baker
Journal:  Sleep Med Clin       Date:  2020-01-03

4.  A comparison of static and dynamic cerebral autoregulation during mild whole-body cold stress in individuals with and without cervical spinal cord injury: a pilot study.

Authors:  Jan W van der Scheer; Yoshi-Ichiro Kamijo; Christof A Leicht; Philip J Millar; Manabu Shibasaki; Victoria L Goosey-Tolfrey; Fumihiro Tajima
Journal:  Spinal Cord       Date:  2018-01-12       Impact factor: 2.772

5.  Cutaneous mitochondrial respirometry: non-invasive monitoring of mitochondrial function.

Authors:  Floor A Harms; Sander I A Bodmer; Nicolaas J H Raat; Egbert G Mik
Journal:  J Clin Monit Comput       Date:  2014-11-12       Impact factor: 2.502

6.  Short Communication: Use of Infrared Thermometers for Cutaneous Temperature Recording: Agreement with the Rectal Temperature in Felis catus.

Authors:  Claudia Giannetto; Giuseppe Acri; Melissa Pennisi; Giuseppe Piccione; Francesca Arfuso; Annastella Falcone; Elisabetta Giudice; Simona Di Pietro
Journal:  Animals (Basel)       Date:  2022-05-16       Impact factor: 3.231

7.  Cold-induced vasoconstriction at forearm and hand skin sites: the effect of age.

Authors:  B R M Kingma; A J H Frijns; W H M Saris; A A van Steenhoven; W D van Marken Lichtenbelt
Journal:  Eur J Appl Physiol       Date:  2010-03-19       Impact factor: 3.078

8.  Wearable materials with embedded synthetic biology sensors for biomolecule detection.

Authors:  Peter Q Nguyen; Luis R Soenksen; Nina M Donghia; Nicolaas M Angenent-Mari; Helena de Puig; Ally Huang; Rose Lee; Shimyn Slomovic; Tommaso Galbersanini; Geoffrey Lansberry; Hani M Sallum; Evan M Zhao; James B Niemi; James J Collins
Journal:  Nat Biotechnol       Date:  2021-06-28       Impact factor: 54.908

9.  Local cooling during hot water immersion improves perceptions without inhibiting the acute interleukin-6 response.

Authors:  R G Mansfield; S P Hoekstra; J J Bill; Christof A Leicht
Journal:  Eur J Appl Physiol       Date:  2021-02-28       Impact factor: 3.078

10.  Cutaneous Respirometry as Novel Technique to Monitor Mitochondrial Function: A Feasibility Study in Healthy Volunteers.

Authors:  Floor Anneleen Harms; Robert Jan Stolker; Egbert Gezinus Mik
Journal:  PLoS One       Date:  2016-07-25       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.