Literature DB >> 9429104

Blood and tissue compatibility of modified polyester: thrombosis, inflammation, and healing.

J A Chinn1, J A Sauter, R E Phillips, W J Kao, J M Anderson, S R Hanson, T R Ashton.   

Abstract

Poly(ethylene terephthalate) (PET) has been reported in literature to be moderately inflammatory and thrombogenic. To moderate the inflammatory response, PET fabric was surface modified by either Fluoropassiv fluoropolymer (FC), or an RGD-containing peptide (RGD). Samples were subsequently autoclave sterilized and implanted subcutaneously in Sprague Dawley rats for 2 to 4 weeks. Retrieved samples were evaluated histopathologically for indications of material toxicity and healing. Minimal acute or chronic inflammation was associated with the fabrics after 2 and 4 week implant duration. However, fibroblast proliferation into FC modified fabric (PET/FC) was less than that into unmodified (PET) and RGD modified fabric (PET/RGD) after 4 weeks, suggesting that FC modification of PET may inhibit excessive tissue growth. Additional samples of modified and unmodified fabrics were placed in stainless steel mesh cages, which were then implanted subcutaneously for 4 weeks. Cellular exudate was extracted weekly and cell concentrations within the exudate measured. Total leukocyte count (TLC) (reflective of local inflammation) at 1 week for PET/RGD was greater than that for PET/FC and PET. TLCs after 4 week implant decreased for all sample groups. In a separate experiment, PET vascular grafts surface modified by either FC or RGD were contacted 1 h with blood using the baboon arteriovenous (AV) shunt model of thrombosis in both the presence and absence of heparin. Accumulation of 111In labeled platelets (reflective of thrombus accumulation) upon grafts was less in the presence of heparin (effect significant at p = 1.2 x 10(-6), two-way ANOVA). Accumulation (in the presence of heparin) upon PET/RGD was less (p = 0.19), and upon PET/FC significantly less (p = 0.016) than that upon the unmodified PET control, suggesting that FC modification of PET may inhibit thrombus accumulation.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9429104     DOI: 10.1002/(sici)1097-4636(19980101)39:1<130::aid-jbm15>3.0.co;2-j

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  6 in total

1.  Interaction of an ionic complementary peptide with a hydrophobic graphite surface.

Authors:  Yuebiao Sheng; Wei Wang; P Chen
Journal:  Protein Sci       Date:  2010-09       Impact factor: 6.725

2.  Characterization of surface modified polyester fabric.

Authors:  Roy Joseph; R Shelma; A Rajeev; C V Muraleedharan
Journal:  J Mater Sci Mater Med       Date:  2008-06-27       Impact factor: 3.896

3.  New resorbable polymeric systems with antithrombogenic activity.

Authors:  G Rodríguez; A Gallardo; J San Román; M Rebuelta; P Bermejo; J Buján; J M Bellón; N G Honduvilla; C Escudero
Journal:  J Mater Sci Mater Med       Date:  1999-12       Impact factor: 3.896

4.  Interleukin-6 expression by cultured human endothelial cells in contact with carbon coated polyethylene terephthalate.

Authors:  E Cenni; D Granchi; G Ciapetti; D Cavedagna; A Corradini; A Di Leo
Journal:  J Mater Sci Mater Med       Date:  2001-04       Impact factor: 3.896

5.  Tethering Cells via Enzymatic Oxidative Crosslinking Enables Mechanotransduction in Non-Cell-Adhesive Materials.

Authors:  Tom Kamperman; Sieger Henke; João F Crispim; Niels G A Willemen; Pieter J Dijkstra; Wooje Lee; Herman L Offerhaus; Martin Neubauer; Alexandra M Smink; Paul de Vos; Bart J de Haan; Marcel Karperien; Su Ryon Shin; Jeroen Leijten
Journal:  Adv Mater       Date:  2021-09-03       Impact factor: 32.086

6.  Modification of hydrophilic and hydrophobic surfaces using an ionic-complementary peptide.

Authors:  Hong Yang; Shan-Yu Fung; Mark Pritzker; P Chen
Journal:  PLoS One       Date:  2007-12-19       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.