Literature DB >> 9429035

Electrical injury from subway third rails: serious injury associated with intermediate voltage contact.

J Rabban1, J Adler, C Rosen, J Blair, R Sheridan.   

Abstract

BACKGROUND: Railway and subway-associated electrical trauma is rare and typically involves high voltage (> 20,000) arc injuries. Not all rail systems utilize such high voltage. We report 16 cases of electrical trauma due to 600 V direct contact with subway 'third' rails.
METHODS: A case series of injured patients presenting to Shriners Burns Institute, Boston or Massachusetts General Hospital between 1970 and 1995 was retrospectively analyzed.
RESULTS: A total of 16 cases was identified. Among seven subway workers, the mechanism of rail contact was unintentional by a tool, a hand or by falling; no deaths occurred. Among nine non-occupational victims, injuries involved suicide attempts, unintentional falls, or risk-taking behavior. This group suffered greater burn severity, operative procedures, and complications; three deaths occurred.
CONCLUSIONS: This is the largest report series of direct electrical trauma from a subway third rail. The high morbidity and mortality from this 600 V contact suggests that the traditional classification of low voltage (< 1000 V) exposure can be subdivided to reflect the serious and lethal potential of intermediate range exposures compared to household range exposures (0-220 V).

Entities:  

Mesh:

Year:  1997        PMID: 9429035     DOI: 10.1016/s0305-4179(97)00033-8

Source DB:  PubMed          Journal:  Burns        ISSN: 0305-4179            Impact factor:   2.744


  4 in total

1.  Public health lessons learned from analysis of New York City subway injuries.

Authors:  Amber A Guth; Andrea O'Neill; H Leon Pachter; Thomas Diflo
Journal:  Am J Public Health       Date:  2006-01-31       Impact factor: 9.308

Review 2.  Suicidal behaviour on subway systems: a review of the epidemiology.

Authors:  Ruwan Ratnayake; Paul S Links; Rahel Eynan
Journal:  J Urban Health       Date:  2007-09-08       Impact factor: 3.671

3.  Pattern of high voltage electrical injuries in the Kashmir valley: a 10-year single centre experience.

Authors:  R A Kasana; P U F Baba; A H Wani
Journal:  Ann Burns Fire Disasters       Date:  2016-12-31

4.  The management of electrical burn.

Authors:  Ashok Surybhanji Gajbhiye; Mona M Meshram; Rekha S Gajaralwar; Amrish P Kathod
Journal:  Indian J Surg       Date:  2012-05-22       Impact factor: 0.656

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.