Differences in bronchodilating potency of salbutamol in Turbuhaler as compared with a pressurized metered-dose inhaler formulation in patients with reversible airway obstruction.

C G Löfdahl1, L Andersson, E Bondesson, L G Carlsson, K Friberg, J Hedner, Y Hörnblad, P Jemsby, A Källén, A Ullman, S Werner, N Svedmyr.   

Abstract

Two studies are presented, with the aim of establishing the dose potency ratio for salbutamol given via Turbuhaler and via a pressurized metered-dose inhaler (pMDI). Both studies were of a double-blind, randomized design. Outpatients with mild-to-moderate chronic reversible airway obstruction were given single doses of salbutamol administered via Turbuhaler and via pMDI. Efficacy and safety variables were measured before and during 6 h after each dose. The first study was a four-way crossover study including 12 patients. The salbutamol doses given were: 50, 100 and 2x100 microg via Turbuhaler and 2x100 microg via pMDI (Ventolin). The study showed that 2x100 microg of salbutamol inhaled via Turbuhaler is more potent than 2x100 microg salbutamol inhaled via a pMDI, and that 100 microg salbutamol via Turbuhaler is at least as potent as 2x100 microg salbutamol inhaled via a pMDI. The second study including 50 patients was a placebo-controlled five-way crossover, study. Two doses of salbutamol via Turbuhaler, 50 and 2x100 microg, and via pMDI, 100 and 2x200 microg, were given. There was a dose-dependent response in forced expiratory volume in one second (FEV1) for both inhalers. Adjusted for differences in baseline FEV1 values, the estimated relative dose potency for Turbuhaler versus pMDI was 1.98:1 (95% confidence interval 12-3.2). These studies showed that the same bronchodilating effect can be achieved when half the dose of salbutamol given via a conventional pressurized metered-dose inhaler is given via Turbuhaler.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9426081     DOI: 10.1183/09031936.97.10112474

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  4 in total

Review 1.  Discriminating measures of bronchodilator drug efficacy and potency.

Authors:  H Buck; M Parry-Billings
Journal:  Br J Clin Pharmacol       Date:  2001-09       Impact factor: 4.335

2.  Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering beta (2 )agonists bronchodilators in asthma.

Authors:  F S Ram; J Wright; D Brocklebank; J E White
Journal:  BMJ       Date:  2001-10-20

3.  Decreased bronchodilating effect of salbutamol in relieving methacholine induced moderate to severe bronchoconstriction during high dose treatment with long acting beta2 agonists.

Authors:  H J van der Woude; T H Winter; R Aalbers
Journal:  Thorax       Date:  2001-07       Impact factor: 9.139

4.  Randomised placebo controlled trial of beta agonist dose reduction in asthma.

Authors:  T W Harrison; J Oborne; P J Wilding; A E Tattersfield
Journal:  Thorax       Date:  1999-02       Impact factor: 9.139

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.