Literature DB >> 9426017

Quantitative coronary angiographic and intravascular ultrasound assessment of a new nonarticulated stent: report from the Advanced Cardiovascular Systems MultiLink stent pilot study.

J P Carrozza1, J B Hermiller, T J Linnemeier, J J Popma, P G Yock, G S Roubin, L S Dean, R E Kuntz, L Robertson, K K Ho, D E Cutlip, D S Baim.   

Abstract

OBJECTIVES: The purpose of this study was to evaluate the safety, feasibility, optimal deployment technique and 1-year clinical outcome for the Advanced Cardiovascular Systems (ACS) MultiLink stent.
BACKGROUND: Optimal stent deployment assessed by quantitative coronary angiography and intravascular ultrasound (IVUS) is associated with improved clinical outcome.
METHODS: Forty-nine consecutive patients with a discrete stenosis in a native coronary artery 3 to 4 mm in diameter were treated with the new, balloon-expandable ACS MultiLink stent. Stent expansion was assessed in all patients using quantitative coronary angiography and serial IVUS imaging after 8-, 12- and 16-atm inflations. Clinical follow-up was obtained at 30 days and 1 year.
RESULTS: All 49 patients had successful placement of a MultiLink stent without death, emergency coronary artery bypass graft surgery or Q wave myocardial infarction. After placement of the MultiLink stent, the minimal lumen diameter increased from 1.24 to 2.98 mm (p < 0.001), and diameter stenosis decreased from 61% to 7% (p = 0.001). Minimal lumen cross-sectional area by IVUS increased progressively after 8, 12 and 16 atm (5.6 to 6.8 to 7.4 mm2, respectively, p < 0.001). However, only 64% of stents achieved a lumen/reference area ratio > or = 70%. No adverse clinical events occurred by 30 days, and by 1 year only one patient (2.0%) required revascularization of the stented artery.
CONCLUSIONS: Treatment of stenoses in native coronary arteries with the MultiLink stent is associated with a high success rate and a low incidence of adverse events by 1 year, despite the fact that the majority of stents did not meet IVUS-defined criteria for "optimal stenting" derived from first-generation devices.

Entities:  

Mesh:

Year:  1998        PMID: 9426017     DOI: 10.1016/s0735-1097(97)00426-9

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  2 in total

1.  Stent expansion: a combination of delivery balloon underexpansion and acute stent recoil reduces predicted stent diameter irrespective of reference vessel size.

Authors:  Shahid Aziz; John L Morris; Raphael A Perry; Rodney H Stables
Journal:  Heart       Date:  2007-05-04       Impact factor: 5.994

2.  Comparison of acute recoil between bioabsorbable poly-L-lactic acid XINSORB stent and metallic stent in porcine model.

Authors:  Yizhe Wu; Li Shen; Qibing Wang; Lei Ge; Jian Xie; Xi Hu; Aijun Sun; Juying Qian; Junbo Ge
Journal:  J Biomed Biotechnol       Date:  2012-10-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.