Y H Chou1, M T Chen, C H Huang.
Abstract
Ultrasound has been used as a convenient examination method to obtain an estimate of the kidney size and parenchymal thickness. The aim of this study was to determine the relationship between the renal parenchymal thickness and individual renal function. Renal ultrasonography to determine parenchymal thickness and 99mTc-DTPA renal scan to detect individual renal function were carried out on 30 patients. The statistic analysis showed poor correlation between these two factors. The correlation coefficients is 0.1 only. However, the correlation coefficients of the difference of bilateral renal parenchymal thickness and the difference of bilateral renal function in the same patient is much higher (r = 0.67). So, it is unreliable to predict the random single renal function based on parenchymal thickness only. However, in the same patient, it is sometimes worthwhile to differentiate bilateral renal function based on the difference of renal parenchymal thickness between the two kidneys.Entities: