Literature DB >> 9425506

Prediction of human femoral bone strength using ultrasound velocity and BMD: an in vitro study.

C F Njeh1, C W Kuo, C M Langton, H I Atrah, C M Boivin.   

Abstract

The stiffness and strength of cancellous bone are important in the management of skeletal diseases such as osteoporosis. These properties are a function not only of bone density but also of bone architecture, some measure of which can be provided by quantitative ultrasound. The ability of quantitative ultrasound and bone mineral density (BMD) to predict stiffness and strength of human femoral heads removed from live subjects during hip replacement was assessed. Stiffness and strength were measured using a uniaxial compression test. Ultrasound velocity was measured using the pulse-submersion technique (McCue CUBAResearch) and BMD using DXA (Lunar DPX-L). Ultrasound velocity (quantitative ultrasound) and stiffness varied with the three orthogonal directions, the highest significance being between the proximo-distal (PD) and antero-posterior (AP) directions (p < 0.0001 for stiffness and p = 0.0003 for velocity). Ultrasound velocity was significantly correlated with compressive bone strength (r = 0.76, p < 0.0001) and stiffness (r = 0.79-0.83, p < 0.0001). BMD was also significantly correlated with compressive strength (r = 0.82, p < 0.0001) and stiffness (r = 0.66-0.81. p < 0.001). Using multiple regression analysis both BMD and velocity were significant predictors of strength (r = 0.88, p = 0.0004 and 0.0054 respectively) and stiffness (r = 0.92, p = 0.0001 and 0.0003 respectively). BMD and velocity were still independent significant predictors of both stiffness (r = 0.93, p < 0.0001 and 0.0001 respectively) and strength (r = 0.89, p < 0.0001 and 0.02) when they were combined as a product (BMDn*Vm). This suggests that BMD measured using DXA, if used in conjunction with ultrasound velocity, may be able to improve osteoporosis risk assessment. The information about femur anisotropy may also be important for hip prosthesis and in vivo modelling.

Entities:  

Mesh:

Year:  1997        PMID: 9425506     DOI: 10.1007/s001980050035

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  22 in total

1.  A numerical method to predict the effects of frequency-dependent attenuation and dispersion on speed of sound estimates in cancellous bone.

Authors:  K A Wear
Journal:  J Acoust Soc Am       Date:  2001-03       Impact factor: 1.840

2.  Inverse problems in cancellous bone: estimation of the ultrasonic properties of fast and slow waves using Bayesian probability theory.

Authors:  Christian C Anderson; Adam Q Bauer; Mark R Holland; Michal Pakula; Pascal Laugier; G Larry Bretthorst; James G Miller
Journal:  J Acoust Soc Am       Date:  2010-11       Impact factor: 1.840

3.  Association of dietary and biochemical measures of vitamin K with quantitative ultrasound of the heel in men and women.

Authors:  R R McLean; S L Booth; D P Kiel; K E Broe; D R Gagnon; K L Tucker; L A Cupples; M T Hannan
Journal:  Osteoporos Int       Date:  2006-01-06       Impact factor: 4.507

Review 4.  Recent developments in trabecular bone characterization using ultrasound.

Authors:  Frédéric Padilla; Pascal Laugier
Journal:  Curr Osteoporos Rep       Date:  2005-06       Impact factor: 5.096

5.  The dependence of time-domain speed-of-sound measurements on center frequency, bandwidth, and transit-time marker in human calcaneus in vitro.

Authors:  Keith A Wear
Journal:  J Acoust Soc Am       Date:  2007-07       Impact factor: 1.840

6.  Mechanisms for attenuation in cancellous-bone-mimicking phantoms.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-11       Impact factor: 2.725

Review 7.  Ultrasonic scattering from cancellous bone: a review.

Authors:  K A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-07       Impact factor: 2.725

8.  A-Mode ultrasound guidance for pedicle screw advancement in ovine vertebral bodies.

Authors:  David T Raphael; Jin Ho Chang; Yao Ping Zhang; David Kudija; Thomas C Chen; K Kirk Shung
Journal:  Spine J       Date:  2010-03-27       Impact factor: 4.166

9.  Enhanced correlation between quantitative ultrasound and structural and mechanical properties of bone using combined transmission-reflection measurement.

Authors:  Liangjun Lin; Wei Lin; Yi-Xian Qin
Journal:  J Acoust Soc Am       Date:  2015-03       Impact factor: 1.840

10.  Measurement of human trabecular bone by novel ultrasonic bone densitometry based on fast and slow waves.

Authors:  T Yamamoto; T Otani; H Hagino; H Katagiri; T Okano; I Mano; R Teshima
Journal:  Osteoporos Int       Date:  2008-11-07       Impact factor: 4.507

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.