Nd:YAG laser clearance of the anterior surface of posterior chamber intraocular lenses.

S J Talks1.   

Abstract

PURPOSE: To demonstrate the use of Nd:YAG laser in clearing the anterior surface of posterior chamber intraocular lenses.
METHOD: Six cases are presented with the following conditions: haemorrhage, inflammatory deposits, a fibrinous papillary membrane, capsulorhexis shrinkage.
RESULTS: Nd:YAG laser was successful in managing each of these cases.
CONCLUSION: With careful use Nd:YAG laser clearance of the anterior surface of a posterior chamber intraocular lens can be carried out successfully without damaging the lens.