Detection of renal artery stenosis with Doppler sonography before and after administration of captopril: value of early systolic rise.

V L Oliva1, G Soulez, D Lesage, V Nicolet, M C Roy, M Courteau, D Froment, P C René, E Thérasse, L Carignan.   

Abstract

OBJECTIVE: The goal of this study was to assess the value of quantitative and qualitative analysis of the early systolic rise on Doppler waveforms obtained before and after administration of captopril in patients suspected of having renal artery stenosis. SUBJECTS AND METHODS: Seventy-one hypertensive patients (135 kidneys) were studied with transrenal Doppler sonography. Ninety-six kidneys were studied again after administration of captopril. All patients also underwent renal angiography. All Doppler studies were independently reviewed by two observers. Specific criteria for Doppler waveform patterns that were applied in the detection of renal artery stenosis included acceleration, acceleration time of early systolic rise, differential velocity of systolic rise, and resistive index. These criteria were then correlated with angiography, and receiver operating characteristic curves were generated.
RESULTS: On the basis of waveform pattern recognition. Doppler sonograms obtained before administration of captopril had a sensitivity of 81% and a specificity of 98% for the detection of renal artery stenosis greater than or equal to 50%. Sensitivity of Doppler sonography obtained after administration of captopril was 100%, and specificity was 100%. For renal artery stenosis greater than or equal to 70%, sensitivity was 94% and specificity was 89% before administration of captopril. The area under the receiver operating characteristic curve for the acceleration criterion was significantly larger after administration of captopril (p = .009) for the detection of renal artery stenosis greater than or equal to 50%. After captopril administration, an acceleration threshold value of 440 cm/sec2 for early systolic rise was associated with a sensitivity of 100% and a specificity of 94% for the detection of renal artery stenosis greater than or equal to 50%.
CONCLUSION: Doppler sonography of the renal arteries performed before administration of captopril appears to be an excellent screening tool in the detection of severe stenosis (> or = 70%). Administration of captopril improves the detection of renal artery stenosis greater than or equal to 50% with Doppler sonography when observers use both morphologic and quantitative criteria.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9423626     DOI: 10.2214/ajr.170.1.9423626

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  4 in total

1.  Correlation between renal blood flow and intrarenal Doppler measurements in canine autotransplanted kidney.

Authors:  Y Tsuji; H Taira
Journal:  Int Urol Nephrol       Date:  2001       Impact factor: 2.370

2.  Investigation of the arterial stiffness on renal artery Doppler sonograms.

Authors:  Mahmut Tokmakçi; Nuri Erdoğan
Journal:  J Med Syst       Date:  2009-04       Impact factor: 4.460

3.  Renal vascular response to angiotensin II inhibition in intensive antihypertensive treatment of essential hypertension.

Authors:  Arkadiusz Lubas; Grzegorz Zelichowski; Agnieszka Próchnicka; Magdalena Wiśniewska; Marek Saracyn; Zofia Wańkowicz
Journal:  Arch Med Sci       Date:  2010-09-07       Impact factor: 3.318

4.  Renal autoregulation in medical therapy of renovascular hypertension.

Authors:  Arkadiusz Lubas; Grzegorz Zelichowski; Agnieszka Próchnicka; Magdalena Wiśniewska; Zofia Wańkowicz
Journal:  Arch Med Sci       Date:  2010-12-29       Impact factor: 3.318

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.