Literature DB >> 9423606

Compliance with recommended follow-up after percutaneous breast core biopsy.

K A Goodman1, R L Birdwell, D M Ikeda.   

Abstract

OBJECTIVE: The purpose of this study was to use information from an established patient tracking system to evaluate patient outcome and assess patient compliance with recommended follow-up after percutaneous breast core biopsy.
MATERIALS AND METHODS: All breast core biopsies performed from January 1994 through February 14, 1996, that used stereotaxic or sonographic guidance were reviewed. Clinical, imaging, and pathologic findings were correlated with patient outcomes established by recommended surgical and nonsurgical follow-up.
RESULTS: Of 160 core biopsies in 153 women, 30 biopsies were performed on the basis of clinical complaints. One hundred thirty lesions were detected by mammography or sonography or both. Of the 70 lesions recommended for surgical excision, 52 (74%) had documented surgical outcomes. Mammographic surveillance was recommended for 90 lesions, of which 10 (11%) had resolved at the time of this study, 49 (54%) were on track toward 3-year lesion stability, 21 (23%) were being followed up elsewhere, four (4%) were lost to physicians, and six (7%) were lost to follow-up for other reasons.
CONCLUSION: Known compliance with follow-up recommendations among these 153 patients who underwent breast core biopsy was higher for patients receiving surgical recommendation (74%) than for patients receiving imaging surveillance recommendation (54%). Problems tracking patients were caused both by loss of patients to follow-up and by incomplete reporting from referring physicians.

Entities:  

Mesh:

Year:  1998        PMID: 9423606     DOI: 10.2214/ajr.170.1.9423606

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  4 in total

Review 1.  Interventions to improve follow-up of abnormal findings in cancer screening.

Authors:  Roshan Bastani; K Robin Yabroff; Ronald E Myers; Beth Glenn
Journal:  Cancer       Date:  2004-09-01       Impact factor: 6.860

2.  Short interval follow-up after a benign concordant MR-guided vacuum assisted breast biopsy--is it worthwhile?

Authors:  Sara D Shaylor; Samantha L Heller; Amy N Melsaether; Dipti Gupta; Avani Gupta; James Babb; Linda Moy
Journal:  Eur Radiol       Date:  2014-03-14       Impact factor: 5.315

3.  False-negative results after stereotactically guided vacuum biopsy.

Authors:  D Peter; J Grünhagen; R Wenke; F K W Schäfer; I Schreer
Journal:  Eur Radiol       Date:  2007-07-19       Impact factor: 5.315

4.  Ultrasonography-guided 14-gauge core biopsy of the breast: results of 7 years of experience.

Authors:  Inha Jung; Min Jung Kim; Hee Jung Moon; Jung Hyun Yoon; Eun-Kyung Kim
Journal:  Ultrasonography       Date:  2017-05-17
  4 in total