Comparison of bond strengths of denture base resins to nickel-chromium-beryllium removable partial denture alloy.

D P NaBadalung1, J M Powers, M E Connelly.   

Abstract

PURPOSE: In vitro bond strengths of a traditional denture base resin (Lucitone 199) and three adhesive denture base resins (Meta-Dent, Meta-Fast with liner, and Meta-Fast without liner) to treated nickel-chromium-beryllium (Ni-Cr-Be) partial denture alloy were tested with four alloy surface pretreatments (sandblast, Met-etch, Rocatec with silane, and Rocatec without silane), with or without primer (Dentsply). The Lucitone 199 resin bonded to the nonprimed sandblasted group was the control group. The hypothesis was the use of alloy pretreatments and/or primer does not improve the bond strength of denture base resins to sandblasted Ni-Cr-Be partial denture alloy.
MATERIAL AND METHODS: Primed and nonprimed bonded specimens were prepared and finished, stored in 37 degrees C distilled water for 24 hours, then debonded in tension on a testing machine. The bond strength was calculated in megapascals (MPa). Five specimens were prepared and tested for each experimental condition, both with and without primer, for a total of 160 specimens.
RESULTS: For three-way analysis of variance, the main effects of resins and treatment were statistically significant (p < 0.05), but the main effect of primer was not statistically significantly (p > 0.05). Without primer, the control group had the lowest bond strength (0 MPa). The three adhesive resin groups produced significantly higher bond strengths than the Lucitone resin groups. For the treated groups, nearly all sandblasted groups produced significantly lower bond strength than the other three treated groups. Meta-Dent to Met-etch treated group had the highest bond strength (23.9 MPa). With primer, the bond strengths of the Lucitone resin groups were significantly higher than the nonprimed groups, and the Lucitone resin-primed Rocatec treated group had the highest bond strength (14.8 MPa). For the three adhesive denture base resins, nearly all primed treated groups had significantly lower bond strengths than nonprimed groups.
CONCLUSIONS: Without primer, the Lucitone resin-sandblast treated group (control) had the lowest bond strength (0 MPa). The Meta-Dent denture base resin with the Met-etch treated group had the highest bond strength (23.9 MPa). With primer, the Lucitone resin-primed Rocatec-silane treated group had the highest bond strength (14.8 MPa). For the adhesive denture base resins, nearly all bond strengths of the primed treated groups were significantly lower than the values of the nonprimed groups.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9421785     DOI: 10.1016/s0022-3913(97)70007-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  2 in total

1.  Comparative evaluation of effect of metal primer and sandblasting on the shear bond strength between heat cured acrylic denture base resin and cobalt-chromium alloy: An in vitro study.

Authors:  Sandeep Kalra; Vishwas Kharsan; Nidhi Mangtani Kalra
Journal:  Contemp Clin Dent       Date:  2015 Jul-Sep

2.  Evaluation of shear bond strength of repair acrylic resin to Co-Cr alloy.

Authors:  Safak Külünk; Tolga Külünk; Duygu Saraç; Seda Cengiz; Seniha Baba
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.