Literature DB >> 9420820

Comparison of gating methods for the real-time analysis of left ventricular function in nonimaging blood pool studies.

B B Beard1, J R Stewart, R G Shiavi, C H Lorenz.   

Abstract

BACKGROUND: Gating methods developed for electrocardiographic-triggered radionuclide ventriculography are being used with nonimaging detectors. These methods have not been compared on the basis of their real-time performance or suitability for determination of load-independent indexes of left ventricular function. This work evaluated the relative merits of different gating methods for nonimaging radionuclude ventriculographic studies, with particular emphasis on their suitability for real-time measurements and the determination of pressure-volume loops. METHODS AND
RESULTS: A computer model was used to investigate the relative accuracy of forward gating, backward gating, and phase-mode gating. The durations of simulated left ventricular time-activity curves were randomly varied. Three acquisition parameters were considered: frame rate, acceptance window, and sample size. Twenty-five studies were performed for each combination of acquisition parameters. Hemodynamic and shape parameters from each study were compared with reference parameters derived directly from the random time-activity curves. Backward gating produced the largest errors under all conditions. For both forward gating and phase-mode gating, ejection fraction was underestimated and time to end systole and normalized peak ejection rate were overestimated. For the hemodynamic parameters, forward gating was marginally superior to phase-mode gating. The mean difference in errors between forward and phase-mode gating was 1.47% (SD 2.78%). However, for root mean square shape error, forward gating was several times worse in every case and seven times worse than phase-mode gating on average.
CONCLUSIONS: Both forward and phase-mode gating are suitable for real-time hemodynamic measurements by nonimaging techniques. The small statistical difference between the methods is not clinically significant. The true shape of the time-activity curve is maintained most accurately by phase-mode gating.

Mesh:

Year:  1995        PMID: 9420820      PMCID: PMC5831181          DOI: 10.1016/s1071-3581(05)80028-5

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  8 in total

1.  Comparison of fixed and variable temporal resolution methods for creating gated cardiac blood-pool image sequences.

Authors:  S L Bacharach; R O Bonow; M V Green
Journal:  J Nucl Med       Date:  1990-01       Impact factor: 10.057

2.  Effect of ischemia on ventricular contractility in patients with coronary artery disease.

Authors:  L J Spaccavento; E D Grassman; W M Briesblatt; R S Schwartz
Journal:  Angiology       Date:  1990-06       Impact factor: 3.619

3.  Effects of gating modes on the analysis of left ventricular function in the presence of heart rate variation.

Authors:  J E Juni; C C Chen
Journal:  J Nucl Med       Date:  1988-07       Impact factor: 10.057

4.  The rate of change of left ventricular volume in man. II. Diastolic events in health and disease.

Authors:  K E Hammermeister; J R Warbasse
Journal:  Circulation       Date:  1974-04       Impact factor: 29.690

5.  The rate of change of left ventricular volume in man. I. Validation and peak systolic ejection rate in health and disease.

Authors:  K E Hammermeister; R C Brooks; J R Warbasse
Journal:  Circulation       Date:  1974-04       Impact factor: 29.690

6.  Blood pressure and heart rate variabilities in normotensive and hypertensive human beings.

Authors:  G Mancia; A Ferrari; L Gregorini; G Parati; G Pomidossi; G Bertinieri; G Grassi; M di Rienzo; A Pedotti; A Zanchetti
Journal:  Circ Res       Date:  1983-07       Impact factor: 17.367

7.  Beat-to-beat left ventricular performance assessed from the equilibrium cardiac blood pool using a computerized nuclear probe.

Authors:  H J Berger; R A Davies; W P Batsford; P B Hoffer; A Gottschalk; B L Zaret
Journal:  Circulation       Date:  1981-01       Impact factor: 29.690

8.  Beat-by-beat validation of ECG gating.

Authors:  S L Bacharach; M V Green; J S Borer; H G Ostrow; R O Bonow; S P Farkas; G S Johnston
Journal:  J Nucl Med       Date:  1980-04       Impact factor: 10.057

  8 in total
  1 in total

1.  A system for postoperative visualization and analysis of left ventricular pressure-volume loops.

Authors:  B B Beard; J R Stewart; T A Fischell
Journal:  Comput Biol Med       Date:  1998-01       Impact factor: 4.589

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.