Literature DB >> 9420818

Preoperative risk stratification by adenosine thallium 201 single-photon emission computed tomography in patients undergoing vascular surgery.

M G Koutelou1, P J Asimacopoulos, J J Mahmarian, K T Kimball, M S Verani.   

Abstract

BACKGROUND: Adenosine perfusion scintigraphy is a powerful technique for diagnosing coronary artery disease and risk stratifying patients with recent myocardial infarction. METHODS AND
RESULTS: We investigated the use of adenosine 201Tl tomography to risk stratify 106 patients undergoing vascular arterial reconstruction consisting of lower limb arterial grafting in 44, aortic aneurysmectomy in 36, and carotid endarterectomy in 26 patients. Abnormal tomograms occurred in 57 patients (54%), 47 (82%) of whom had reversible perfusion defects. There were three postoperative deaths, all in the group that underwent aortic aneurysmectomy. Another patient with an aortic aneurysm had unstable angina and one patient who underwent lower limb arterial surgery had pulmonary edema after surgery. No patient without transient defects had an event (negative predictive value 100%). Cardiac events occurred only in patients with transient perfusion defects. However, only 5 of 47 such patients had events (positive predictive value 11%). The perfusion defect size (23% +/- 14% vs 8.9% +/- 135; p = 0.034) and the ischemic fraction (20% +/- 16% vs 5.6% +/- 8.9%; p = 0.009) were 2.5- and 3.5-fold larger, respectively, in patients with than in those without events. A history of diabetes mellitus or previous infarction did not enhance the predictive value of the test.
CONCLUSION: Thus absence of reversible hypoperfusion during adenosine scintigraphy ensures virtual absence of postoperative cardiac events. Patients undergoing aortic aneurysmectomy may be targeted preferentially for risk-stratification strategies in the future.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 9420818     DOI: 10.1016/s1071-3581(05)80026-1

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  23 in total

1.  Cardiac prognosis in noncardiac geriatric surgery.

Authors:  M C Gerson; J M Hurst; V S Hertzberg; P A Doogan; M B Cochran; S P Lim; N McCall; R J Adolph
Journal:  Ann Intern Med       Date:  1985-12       Impact factor: 25.391

Review 2.  Preoperative cardiac risk assessment for patients having peripheral vascular surgery.

Authors:  T Wong; A S Detsky
Journal:  Ann Intern Med       Date:  1992-05-01       Impact factor: 25.391

3.  Usefulness of semiquantitative analysis of dipyridamole-thallium-201 redistribution for improving risk stratification before vascular surgery.

Authors:  J R Levinson; C A Boucher; C M Coley; T E Guiney; H W Strauss; K A Eagle
Journal:  Am J Cardiol       Date:  1990-08-15       Impact factor: 2.778

4.  Quantification of infarct size by 201Tl single-photon emission computed tomography during acute myocardial infarction in humans. Comparison with enzymatic estimates.

Authors:  J J Mahmarian; C M Pratt; S Borges-Neto; W R Cashion; R Roberts; M S Verani
Journal:  Circulation       Date:  1988-10       Impact factor: 29.690

5.  Dipyridamole thallium 201 scintigraphy to detect coronary artery disease before abdominal aortic surgery.

Authors:  B S Cutler; J A Leppo
Journal:  J Vasc Surg       Date:  1987-01       Impact factor: 4.268

6.  Predicting the extent and location of coronary artery disease in acute myocardial infarction by echocardiography during dobutamine infusion.

Authors:  C Berthe; L A Pierard; M Hiernaux; G Trotteur; P Lempereur; J Carlier; H E Kulbertus
Journal:  Am J Cardiol       Date:  1986-12-01       Impact factor: 2.778

7.  Diagnosis of coronary artery disease by controlled coronary vasodilation with adenosine and thallium-201 scintigraphy in patients unable to exercise.

Authors:  M S Verani; J J Mahmarian; J B Hixson; T M Boyce; R A Staudacher
Journal:  Circulation       Date:  1990-07       Impact factor: 29.690

8.  Determination of cardiac risk by dipyridamole-thallium imaging before peripheral vascular surgery.

Authors:  C A Boucher; D C Brewster; R C Darling; R D Okada; H W Strauss; G M Pohost
Journal:  N Engl J Med       Date:  1985-02-14       Impact factor: 91.245

9.  The value of the radionuclide angiogram in the prediction of perioperative myocardial infarction in patients undergoing lower extremity revascularization procedures.

Authors:  P F Pasternack; A M Imparato; T S Riles; F G Baumann; G Bear; P J Lamparello; D Benjamin; J Sanger; E Kramer
Journal:  Circulation       Date:  1985-09       Impact factor: 29.690

10.  Combining clinical and thallium data optimizes preoperative assessment of cardiac risk before major vascular surgery.

Authors:  K A Eagle; C M Coley; J B Newell; D C Brewster; R C Darling; H W Strauss; T E Guiney; C A Boucher
Journal:  Ann Intern Med       Date:  1989-06-01       Impact factor: 25.391

View more
  5 in total

Review 1.  Advances in nuclear cardiology: preoperative risk stratification.

Authors:  Kenneth A Brown
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

Review 2.  The question: to test or not to test in preoperative cardiac risk evaluation.

Authors:  J A Leppo; S T Dahlberg
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

3.  Pharmacologic stress perfusion imaging with adenosine: role of simultaneous low-level treadmill exercise.

Authors:  Habib Samady; Frans J Th Wackers; Tammy M Joska; Barry L Zaret; Diwakar Jain
Journal:  J Nucl Cardiol       Date:  2002 Mar-Apr       Impact factor: 5.952

4.  Prevalence and predictors of myocardial ischemia by preoperative myocardial perfusion single photon emission computed tomography in patients undergoing noncardiac surgery.

Authors:  Abdelkareem Saleh Al-Oweidi; Hesham Albabtain; Suleiman M Kharabsheh; Peter Kimme; Mahmoud Almustafa; Samer Seder; Mohamed Shoukri; Ahmed L Fathala
Journal:  Ann Saudi Med       Date:  2017 Nov-Dec       Impact factor: 1.526

Review 5.  Myocardial perfusion scintigraphy: the evidence.

Authors:  S R Underwood; C Anagnostopoulos; M Cerqueira; P J Ell; E J Flint; M Harbinson; A D Kelion; A Al-Mohammad; E M Prvulovich; L J Shaw; A C Tweddel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

  5 in total