Literature DB >> 9420077

Laser-assisted neuroendoscopy using a neodymium-yttrium aluminum garnet or diode contact laser with pretreated fiber tips.

W P Vandertop1, R M Verdaasdonk, C F van Swol.   

Abstract

OBJECT: Although lasers have proved to be valuable in neuroendoscopy, surgeons are still not comfortable using high-energy laser endoscopic probes in proximity to vital structures such as the basilar artery in third ventriculostomy. The authors have developed a special laser catheter for use in neuroendoscopy; the object of this paper is to present their experimental and clinical experiences using the catheter.
METHODS: This laser catheter is fitted with an atraumatic ball-shaped fiber tip that is pretreated with a layer of carbon particles. These carbon particles absorb approximately 90% of the energy emitted, which is very effectively converted into heat. As the heat is generated in this very thin layer of carbon coating, the temperature at the surface of the ball-shaped tip reaches ablative temperatures instantly at powers of only a few watts per second, which has enabled the authors to limit drastically the amount of laser light used and the length of exposure needed, thereby increasing safety even around critical structures.
CONCLUSIONS: The authors present experimental data and their clinical experience using these pretreated fiber tips with a neodymium-yttrium aluminum garnet contact laser or a diode contact laser in 49 patients (22 males and 27 females) and a variety of procedures: third ventriculocistemostomy (33 patients), cyst fenestration (nine patients), colloid cyst resection (six patients), and fenestration of the septum pellucidum (one patient). There was no instance of mortality or increased morbidity. To date, the procedure success rate is 100% and the overall outcome success rate is 86%. The authors conclude that pretreated atraumatic ball-shaped fiber tips now make laser application safe and effective in a variety of neuroendoscopic procedures. Because of their low power range (only several watts), compact diode lasers will be the energy source of first choice.

Entities:  

Mesh:

Year:  1998        PMID: 9420077     DOI: 10.3171/jns.1998.88.1.0082

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  8 in total

Review 1.  Long-term complications and definition of failure of neuroendoscopic procedures.

Authors:  Tjemme Beems; J Andre Grotenhuis
Journal:  Childs Nerv Syst       Date:  2004-06-10       Impact factor: 1.475

2.  Anterior trans-frontal endoscopic management of colloid cyst: an effective, safe, and elegant way of treatment. Case series and technical note from a multicenter prospective study.

Authors:  S Chibbaro; C Champeaux; P Poczos; M Cardarelli; F Di Rocco; C Iaccarino; F Servadei; L Tigan; D Chaussemy; B George; S Froelich; P Kehrli; A Romano
Journal:  Neurosurg Rev       Date:  2013-12-19       Impact factor: 3.042

Review 3.  Shunts vs endoscopic third ventriculostomy in infants: are there different types and/or rates of complications? A review.

Authors:  C Di Rocco; L Massimi; G Tamburrini
Journal:  Childs Nerv Syst       Date:  2006-10-20       Impact factor: 1.475

Review 4.  Endoscopic third ventriculostomy for obstructive hydrocephalus.

Authors:  Dieter Hellwig; Joachim Andreas Grotenhuis; Wuttipong Tirakotai; Thomas Riegel; Dirk Michael Schulte; Bernhard Ludwig Bauer; Helmut Bertalanffy
Journal:  Neurosurg Rev       Date:  2004-11-27       Impact factor: 3.042

5.  First experiences with a 2.0-microm near infrared laser system for neuroendoscopy.

Authors:  H C Ludwig; T Kruschat; T Knobloch; H-O Teichmann; K Rostasy; V Rohde
Journal:  Neurosurg Rev       Date:  2007-05-04       Impact factor: 2.800

Review 6.  Laser application in neurosurgery.

Authors:  Evgenii Belykh; Kaan Yagmurlu; Nikolay L Martirosyan; Ting Lei; Mohammadhassan Izadyyazdanabadi; Kashif M Malik; Vadim A Byvaltsev; Peter Nakaji; Mark C Preul
Journal:  Surg Neurol Int       Date:  2017-11-09

7.  Surgical treatments for post-intubation laryngotracheal stenosis in patients with central nervous system injuries.

Authors:  Stella Chin-Shaw Tsai; Frank Cheau-Feng Lin
Journal:  Medicine (Baltimore)       Date:  2020-01       Impact factor: 1.889

8.  Endoscopic Treatment of Hydrocephalus with Minimal Resources: Resource Utilization and Indigenous Innovation in Developing Countries like India.

Authors:  Deepak Kumar Jha; Mukul Jain; Ishita Pant; Rima Kumari; Renu Goyal; Arvind Arya; Suman Kushwaha
Journal:  Asian J Neurosurg       Date:  2018 Jul-Sep
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.