Literature DB >> 9416911

Effect of altering filling pattern on diastolic pressure-volume curve.

T J Fraites1, A Saeki, D A Kass.   

Abstract

BACKGROUND: The early-to-late ventricular filling ratio (E:A) is widely used to index diastolic function. While filling patterns reflect diastolic properties, they can also modulate chamber pressures due to myocardial viscoelasticity. We hypothesized that such feedback can potentially temper effects of delayed relaxation and/or volume loading on diastolic pressures. METHODS AND
RESULTS: Six isolated blood-perfused canine left ventricles were studied with ejection and filling controlled by an intracavitary volume servo-pump. Diastolic filling was determined by a simulated atrial pressure source that was either constant or varied to yield dual-phase filling at a specified E:A ratio. E:A ratio was randomly set to 3:1, 1:3, or 1:1, and data were recorded at each ratio at three different preloads. With principally early filling (E:A=3:1), diastolic pressure rise from viscosity increased in proportion with the relaxation time constant (r=.91, P<.0001). However, this dependence was lost as E:A ratio declined (eg, P=.63 for E:A 1:3). Furthermore, E:A=3:1 yielded 37% to 50% lower end-diastolic pressures at similar volumes (versus E:A=1:3) as initial viscous forces decayed. Offsetting early and late filling effects led to little net change in mean diastolic pressure independent of E:A ratio or preload.
CONCLUSIONS: Diastolic filling pattern itself influences chamber pressures early and late in diastole due to viscoelasticity, with larger net effects on end-diastolic pressure. Since E:A ratio normally falls with delayed relaxation but rises with higher preload or reduced compliance, the present results suggest that changes in filling pattern may modulate direct effects of such factors on elevating diastolic pressure.

Entities:  

Mesh:

Year:  1997        PMID: 9416911     DOI: 10.1161/01.cir.96.12.4408

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  6 in total

1.  [Is standard-echocardiography sufficient for identification of responders?].

Authors:  M Neuss; P Flach; T Ali; C Butter
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2006

2.  Doppler mitral inflow variables time course after treadmill stress echo with and without ischemic response.

Authors:  Fabijan Lulić; Zdravko Virag
Journal:  Int J Cardiovasc Imaging       Date:  2022-02-26       Impact factor: 2.357

3.  Need for Speed: The Importance of Physiological Strain Rates in Determining Myocardial Stiffness.

Authors:  Matthew A Caporizzo; Benjamin L Prosser
Journal:  Front Physiol       Date:  2021-07-30       Impact factor: 4.755

Review 4.  The microtubule cytoskeleton in cardiac mechanics and heart failure.

Authors:  Matthew A Caporizzo; Benjamin L Prosser
Journal:  Nat Rev Cardiol       Date:  2022-04-19       Impact factor: 49.421

5.  Gender differences in diastolic function among youth.

Authors:  G K Kapuku; H C Davis; N Shah; A M McMillan; G A Harshfield
Journal:  Pediatr Cardiol       Date:  2007-09-25       Impact factor: 1.655

6.  Microtubules Increase Diastolic Stiffness in Failing Human Cardiomyocytes and Myocardium.

Authors:  Matthew A Caporizzo; Christina Yingxian Chen; Ken Bedi; Kenneth B Margulies; Benjamin L Prosser
Journal:  Circulation       Date:  2020-01-16       Impact factor: 29.690

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.