Literature DB >> 9412883

The incidence of artery puncture with central venous cannulation using a modified technique for detection and prevention of arterial cannulation.

W C Oliver1, G A Nuttall, F M Beynen, H S Raimundo, J P Abenstein, J J Arnold.   

Abstract

BACKGROUND: Cannulation of the central circulation is essential for management of patients who require major surgery, and for patients who are critically ill. Arterial puncture is the most frequent complication associated with central venous cannulation, and is potentially fatal. Detection of arterial puncture can be problematic, especially in patients with cyanotic congenital heart disease.
METHODS: One thousand eleven consecutive cardiothoracic and vascular surgical patients who required central venous cannulation were studied using a new technique for detection of arterial puncture and prevention of arterial cannulation. This technique involves continuous pressure transduction of the steel introducer needle. Central venous cannulation was attempted in all patients. The sites of attempted catheterizations, number of arterial punctures and cannulations, and the number of successful catheterizations were noted. All patients were treated in accordance with standard anesthetic and surgical techniques in the institution.
RESULTS: One thousand one hundred seventy-two central venous catheters were placed. The overall success rate was 99.6%. The incidence of arterial puncture was 9.3% for central venous cannulation attempts of the internal jugular, subclavian, and femoral veins. No arterial cannulation occurred, and none of the patients had significant complications. Congenital heart disease patients had a higher incidence of arterial puncture (14.1%) and a lower rate (96.8%) of successful cannulation.
CONCLUSION: Pressure transduction of the steel needle is a useful technique for detecting arterial puncture and preventing arterial cannulation during attempts to achieve central venous cannulation.

Entities:  

Mesh:

Year:  1997        PMID: 9412883     DOI: 10.1016/s1053-0770(97)90119-1

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  18 in total

Review 1.  International evidence-based recommendations on ultrasound-guided vascular access.

Authors:  Massimo Lamperti; Andrew R Bodenham; Mauro Pittiruti; Michael Blaivas; John G Augoustides; Mahmoud Elbarbary; Thierry Pirotte; Dimitrios Karakitsos; Jack Ledonne; Stephanie Doniger; Giancarlo Scoppettuolo; David Feller-Kopman; Wolfram Schummer; Roberto Biffi; Eric Desruennes; Lawrence A Melniker; Susan T Verghese
Journal:  Intensive Care Med       Date:  2012-05-22       Impact factor: 17.440

2.  Complication of central venous cannulation.

Authors:  J Rajinikanth; Edwin Stephen; Sunil Agarwal
Journal:  Can J Surg       Date:  2008-10       Impact factor: 2.089

Review 3.  Assistive technology for ultrasound-guided central venous catheter placement.

Authors:  Mohammad Ikhsan; Kok Kiong Tan; Andi Sudjana Putra
Journal:  J Med Ultrason (2001)       Date:  2017-04-19       Impact factor: 1.314

Review 4.  A delayed diagnosis of a retained guidewire during central venous catheterisation: a case report and review of the literature.

Authors:  Yasemin Gunduz; Mehmet Bulent Vatan; Altug Osken; Mehmet Akif Cakar
Journal:  BMJ Case Rep       Date:  2012-11-19

5.  Absence of the Right Internal Jugular Vein During Ultrasound-Guided Cannulation.

Authors:  Ali Alagöz; Mehtap Tunç; Hilal Sazak; Polat Pehlivanoğlu; Atila Gökçek; Fatma Ulus
Journal:  Turk J Anaesthesiol Reanim       Date:  2015-02-16

6.  Investigating the Effect of Simulator Functional Fidelity and Personalized Feedback on Central Venous Catheterization Training.

Authors:  Mary A Yovanoff; Hong-En Chen; David F Pepley; Katelin A Mirkin; David C Han; Jason Z Moore; Scarlett R Miller
Journal:  J Surg Educ       Date:  2018-03-21       Impact factor: 2.891

7.  Iatrogenic intramural hematoma of the ascending aorta complicating inadvertent arterial cannulation during central venous catheter placement. A case report and review of the literature.

Authors:  Mafdy Basta
Journal:  Ann Card Anaesth       Date:  2020 Oct-Dec

8.  From the simulation center to the bedside: Validating the efficacy of a dynamic haptic robotic trainer in internal jugular central venous catheter placement.

Authors:  Hong-En Chen; Cheyenne C Sonntag; Katelin A Mirkin; David F Pepley; David C Han; Jason Z Moore; Scarlett R Miller
Journal:  Am J Surg       Date:  2019-10-21       Impact factor: 2.565

9.  Fatal airway obstruction following arterial trauma during internal jugular venous cannulation.

Authors:  Aparna Williams; Ashu S Mathai; Gaurav Bhatia; John Abraham
Journal:  Indian J Crit Care Med       Date:  2010-10

10.  Role of chest X-ray in citing central venous catheter tip: A few case reports with a brief review of the literature.

Authors:  Achuthan Nair Venugopal; Rachel Cherian Koshy; Sumod M Koshy
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-07
View more