Literature DB >> 9410624

[Acoustic reflection position monitoring of tracheal cannulae. A contribution to quality assurance?].

M Kunkel1, U Wahlmann, W Wagner.   

Abstract

Non-invasive acoustic airway monitoring was evaluated in an experimental study. Recording amplitude and travel time of acoustic pulse response, an area-distance function of the cross sectional dimensions of the endotracheal tube and the adjacent airway was calculated to obtain an acoustic pattern of the airway. Measurements on models and excised human cadaver lungs were performed to discover whether displacement or obstruction of the artificial airway can be detected in the acoustic equivalent. Regression analysis revealed a close correlation between displacement of tracheostomy tubes and the shifting of the acoustic area-distance function (corr. coeff. 0.97-1). Dispersion analysis confirmed reasonable reliability (coeff. of variation 0.6-2.1%). Location and amount of obstruction could likewise be identified. Thus acoustic mapping provides an adequate approximation of the true geometry of tracheostomy and endotracheal tubes. We conclude that acoustic monitoring may provide a powerful tool to achieve primary prevention of airway disturbances in intubated and mechanically ventilated patients, as geometrical changes of airway configuration can be detected even before they cause substantial effects on respiratory metabolism.

Entities:  

Mesh:

Year:  1997        PMID: 9410624     DOI: 10.1007/BF03043536

Source DB:  PubMed          Journal:  Mund Kiefer Gesichtschir        ISSN: 1432-9417


  16 in total

Review 1.  [Verification of the endotracheal tube placement].

Authors:  G Kreienbühl
Journal:  Anaesthesist       Date:  1992-09       Impact factor: 1.041

2.  Airway geometry by analysis of acoustic pulse response measurements.

Authors:  A C Jackson; J P Butler; E J Millet; F G Hoppin; S V Dawson
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1977-09

Review 3.  Esophageal intubation: a review of detection techniques.

Authors:  P K Birmingham; F W Cheney; R J Ward
Journal:  Anesth Analg       Date:  1986-08       Impact factor: 5.108

4.  Adverse respiratory events in anesthesia: a closed claims analysis.

Authors:  R A Caplan; K L Posner; R J Ward; F W Cheney
Journal:  Anesthesiology       Date:  1990-05       Impact factor: 7.892

5.  Acoustic rhinometry: evaluation of nasal cavity geometry by acoustic reflection.

Authors:  O Hilberg; A C Jackson; D L Swift; O F Pedersen
Journal:  J Appl Physiol (1985)       Date:  1989-01

6.  Complications of dislodged tracheostomy.

Authors:  H A Vyvyan
Journal:  Anaesthesia       Date:  1994-06       Impact factor: 6.955

7.  [Use of fibroptic intubation in oral and maxillofacial surgery].

Authors:  P P Kleemann; H Scheunemann
Journal:  Dtsch Z Mund Kiefer Gesichtschir       Date:  1984 Jan-Feb

8.  Efficacy of daily routine chest radiographs in intubated, mechanically ventilated patients.

Authors:  J B Hall; S R White; T Karrison
Journal:  Crit Care Med       Date:  1991-05       Impact factor: 7.598

9.  Prevention of intraoperative anesthesia accidents and related severe injury through safety monitoring.

Authors:  J H Eichhorn
Journal:  Anesthesiology       Date:  1989-04       Impact factor: 7.892

10.  Prospective evaluation of a nonradiographic device for determination of endotracheal tube position in children.

Authors:  G J Hauser; E Muir; L M Kline; T Scheller; P R Holbrook
Journal:  Crit Care Med       Date:  1990-07       Impact factor: 7.598

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.