Literature DB >> 9409896

[Hygienic processing of dental transmission instruments (handpieces and instruments, turbines) in dental practice].

W Gräf1, B Kunz, B Loisl.   

Abstract

The efficacy of a steam disinfection method for the processing of used instruments in dental practice was tested with 274 high-speed turbines and handpieces. The instruments treated with streaming steam were both taken out of the dental practice of treatment and artificially contaminated with five different test-microorganisms (E. coli, P. aeruginosa, S. aureus, E. faecium, C. albicans) and different concentrations of serum (1%, 10%, 20%). In spite of the narrow channels of these instruments a microbial reduction of more than 5 log10 steps could be achieved in all cases. Thus dental high-speed turbines and handpieces can reliably be disinfected with streaming steam.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 9409896

Source DB:  PubMed          Journal:  Zentralbl Hyg Umweltmed        ISSN: 0934-8859


  1 in total

1.  Development of a validated process for manual preparation of dental transmission instruments.

Authors:  Andre Büchter; Birgit Kruse-Loesler
Journal:  Clin Oral Investig       Date:  2010-05-19       Impact factor: 3.573