Literature DB >> 9407301

Synthetic scleral reinforcement materials. III. Changes in surface and bulk physical properties.

J T Jacob1, J J Lin, S P Mikal.   

Abstract

Changes in the physical properties of polymer materials during implantation in the biological environment can directly affect the ultimate performance of the polymer and/or device. We implanted four types of extraocular bands (porous, solid, composite, and patched) made from 11 types of materials in rabbit eyes and examined the changes in the physical strength and polymer structure of the implanted bands in terms of tensile strength measurements, creep analysis, and attenuated total internal reflectance--Fourier transform infrared spectroscopy (ATR-FTIR) at intervals up to 18 months after implantation. Most of the materials showed increases in tensile strength over the first 6 months in situ in the rabbit eye, followed by significant decreases between 6 and 18 months. Polymer bands that had been implanted for 18 months generally exhibited less creep behavior than unimplanted controls; for most of the bands, creep values ranged from 0% to 10% of the original length. ATR-FTIR of the solid bands and surface coatings showed protein deposition on all of the materials examined, with silicone materials and coatings least affected. Thirty-degree ATR-FTIR scans detected significant changes in the polymer structure for two of the band types: one solid (polyether urethane) and one porous (porous polyacrylate). In general, expanded polytetrafluoroethylene was the most stable in terms of tensile strength and creep. The least stable bands (composite bands made with porous polyurethane) were those that had undergone hydrolytic and/or oxidative degradation and chain scission of the polymer or alteration of the bond between the two materials making up the composite. These changes in physical properties and polymer structure observed after 18 months of implantation support the idea that polymer implant materials should be followed closely over several years in vivo to determine their suitability prior to use in humans.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9407301     DOI: 10.1002/(sici)1097-4636(19971215)37:4<525::aid-jbm11>3.0.co;2-7

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  3 in total

1.  Scar remodeling after strabismus surgery.

Authors:  I H Ludwig
Journal:  Trans Am Ophthalmol Soc       Date:  1999

2.  Effects of poly(2-hydroxyethyl methacrylate) and poly(vinyl-pyrrolidone) hydrogel implants on myopic and normal chick sclera.

Authors:  James Su; Elena Iomdina; Elena Tarutta; Brian Ward; Jie Song; Christine F Wildsoet
Journal:  Exp Eye Res       Date:  2008-12-11       Impact factor: 3.467

3.  Scleral Cross-Linking Using Riboflavin UVA Irradiation for the Prevention of Myopia Progression in a Guinea Pig Model: Blocked Axial Extension and Altered Scleral Microstructure.

Authors:  Shuai Liu; Shengjie Li; Bingjie Wang; Xiao Lin; Yi Wu; Hong Liu; Xiaomei Qu; Jinhui Dai; Xingtao Zhou; Hao Zhou
Journal:  PLoS One       Date:  2016-11-09       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.