Literature DB >> 9404140

[Which laryngoscope is the most stressful in laryngoscopy; Macintosh, Miller, or McCoy?].

T Nishiyama1, T Higashizawa, H Bito, A Konishi, T Sakai.   

Abstract

Stress responses during laryngoscopy were compared among the situations using three different laryngoscopes, Macintosh (curved standard blade), Miller (straight blade), or McCoy (levering). Blood pressure, heart rate (in 58 patients) and plasma concentration of catecholamines (in 29 patients) were measured before, during and after laryngoscopy without tracheal intubation. Systolic blood pressure after laryngoscopy was significantly higher in the Miller group than in other two groups. Plasma epinephrine concentrations after laryngoscopy in the McCoy group were lower than other two groups. Heart rate and plasma norepinephrine concentration were not different among the three groups. These results suggest that the stress response during laryngoscopy without intubation is the biggest in using the Miller laryngoscope and the smallest in using the McCoy laryngoscope.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9404140

Source DB:  PubMed          Journal:  Masui        ISSN: 0021-4892


  5 in total

1.  Effect of laryngoscopy on middle ear pressure during anaesthesia induction.

Authors:  Semih Degerli; Baran Acar; Mehmet Sahap; Eyup Horasanlı
Journal:  Int J Clin Exp Med       Date:  2013-09-25

2.  Comparison of Hemodynamic Response to Laryngoscopy Using Miller and McCoy Blade.

Authors:  Thejeswini Mahadevaiah; Deepak T S; Roopa Rani; Vikas K N; Shwetha G M
Journal:  Cureus       Date:  2022-05-11

3.  Comparison of hemodynamic responses to intubation: Flexible fiberoptic bronchoscope versus McCoy laryngoscope in presence of rigid cervical collar simulating cervical immobilization for traumatic cervical spine.

Authors:  Nitesh Gill; Shobha Purohit; Poonam Kalra; Tarun Lall; Avneesh Khare
Journal:  Anesth Essays Res       Date:  2015 Sep-Dec

4.  Randomized controlled study comparing the hemodynamic response to laryngoscopy and endotracheal intubation with McCoy, Macintosh, and C-MAC laryngoscopes in adult patients.

Authors:  Faiza Sulaiman Buhari; Venkatesh Selvaraj
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2016 Oct-Dec

5.  Comparison of hemodynamic responses to laryngoscopy and intubation using Macintosh or McCoy or C-MAC laryngoscope during uniform depth of anesthesia monitored by entropy.

Authors:  M Rajasekhar; Monu Yadav; Dilip Kulkarni; R Gopinath
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2020-10-16
  5 in total