Literature DB >> 9404040

Rapid determination of corticosteroids in urine by combined solid phase microextraction/liquid chromatography/mass spectrometry.

D A Volmer1, J P Hui.   

Abstract

Solid-phase microextraction combined with fast short-column liquid chromatography/mass spectrometry (SPME/LC/MS) was used for isolating and analysing 11 corticosteroids and 2 steroid conjugates from urine samples. Several SPME parameters such as polarity of fibres, extraction time and effect of ionic strength, were investigated, and their impact on the SPME/LC/MS technique was studied. To demonstrate the potential of the SPME/LC/MS method, its application to the determination of steroids in human urine was investigated. The method was shown to be sensitive with detection limits between 4 and 30 ng/mL and precision between 4.9 and 11.1% RSD through the use of an internal standard technique. The versatility of the method was also exhibited by its excellent linearity in the concentration range of 20 to 20,000 ng/mL in urine for all investigated compounds. A comparison of the SPME/LC/MS method with LC/MS methods utilizing traditional sample preparation techniques, shows that the former offers similar performance in terms of precision, linearity and detection limits, but is clearly easier to use and faster to perform.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9404040     DOI: 10.1002/(SICI)1097-0231(199711)11:17<1926::AID-RCM97>3.0.CO;2-2

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  4 in total

1.  Automated solid-phase microextraction and thin-film microextraction for high-throughput analysis of biological fluids and ligand-receptor binding studies.

Authors:  Dajana Vuckovic; Erasmus Cudjoe; Florin Marcel Musteata; Janusz Pawliszyn
Journal:  Nat Protoc       Date:  2010-01-07       Impact factor: 13.491

2.  Rapid screening assay of congenital adrenal hyperplasia by measuring 17 alpha-hydroxyprogesterone with high-performance liquid chromatography/electrospray ionization tandem mass spectrometry from dried blood spots.

Authors:  Chien-Chen Lai; Chang-Hai Tsai; Fuu-Jen Tsai; Jer-Yuarn Wu; Wei-De Lin; Cheng-Chun Lee
Journal:  J Clin Lab Anal       Date:  2002       Impact factor: 2.352

3.  Mass spectrometric assay and physiological-pharmacological activity of androgenic neurosteroids.

Authors:  Doodipala S Reddy
Journal:  Neurochem Int       Date:  2007-06-13       Impact factor: 3.921

4.  Determination of Endocrine Disrupting Chemicals in Water and Wastewater Samples by Liquid Chromatography-Negative Ion Electrospray Ionization-Tandem Mass Spectrometry.

Authors:  Ghada Aborkhees; Renata Raina-Fulton; Ondiveerapan Thirunavokkarasu
Journal:  Molecules       Date:  2020-08-27       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.